Immunochromatographic techniques - a critical review

被引:90
作者
Weller, MG [1 ]
机构
[1] Tech Univ Munich, Inst Hydrochem, D-81377 Munich, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 6-7期
关键词
D O I
10.1007/s002160051558
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hyphenated techniques have become very popular during the last decade. Nevertheless, the use of biochemical methods, such as immunoassays, in conjunction with instrumental methods, such as chromatography, have not gained widespread acceptance. This review critically discusses many of the implemented and potential options for such coupled systems or components, which might be useful for such systems, including immunoaffinity extraction, immunoaffinity chromatography, immunochemical detectors, immunoblotting, receptor assays, enzyme inhibition assays, displacement assays, flow-injection immunoassays, miniaturized techniques and stationary phases such as restricted access materials or molecularly imprinted polymers. The performance of immunochromatographic systems is discussed regarding their ability to solve highly complex and demanding analytical problems.
引用
收藏
页码:635 / 645
页数:11
相关论文
共 93 条
[81]  
Thurman E.M., 1998, Solid-phase extraction: principles and practice
[82]  
TomMoy M, 1995, ACS SYM SER, V613, P9
[83]   Flow-through fluorescence immunosensor for atrazine determination [J].
Turiel, E ;
Fernández, P ;
Pérez-Conde, C ;
Gutiérrez, AM ;
Cámara, C .
TALANTA, 1998, 47 (05) :1255-1261
[84]   DRUG ASSAY USING ANTIBODY MIMICS MADE BY MOLECULAR IMPRINTING [J].
VLATAKIS, G ;
ANDERSSON, LI ;
MULLER, R ;
MOSBACH, K .
NATURE, 1993, 361 (6413) :645-647
[85]   Micellar electrokinetic chromatography separations and analyses of biological samples on a cyclic planar microstructure [J].
vonHeeren, F ;
Verpoorte, E ;
Manz, A ;
Thormann, W .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2044-2053
[86]   Novel concepts for the immunological detection of bound residues [J].
Weller, MG ;
Zeck, A ;
Pfortner, P ;
Simon, E ;
Niessner, R .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 75 (1-2) :201-215
[87]   Highly parallel affinity sensor for the detection of environmental contaminants in water [J].
Weller, MG ;
Schuetz, AJ ;
Winklmair, M ;
Niessner, R .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :29-41
[88]   AUTOMATED MONITOR SYSTEMS FOR THE CONTINUOUS SURVEILLANCE OF ENVIRONMENTAL-SAMPLES [J].
WIDMER, HM ;
ERARD, JF ;
GRASS, G .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1984, 18 (1-2) :1-10
[89]   Immunochemical array for the identification of cross-reacting analytes [J].
Winklmair, M ;
Schuetz, AJ ;
Weller, MG ;
Niessner, R .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (08) :731-737
[90]   MOLECULAR IMPRINTING IN CROSS-LINKED MATERIALS WITH THE AID OF MOLECULAR TEMPLATES - A WAY TOWARDS ARTIFICIAL ANTIBODIES [J].
WULFF, G .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1995, 34 (17) :1812-1832