Operation of a miniature redox hydrogel-based pyruvate sensor in undiluted deoxygenated calf serum

被引:53
作者
Gajovic, N [1 ]
Binyamin, G
Warsinke, A
Scheller, FW
Heller, A
机构
[1] Univ Potsdam, Biotechnologiepark Luckenwalde, Inst Biochem & Mol Physiol, D-14943 Luckenwalde, Germany
[2] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
关键词
D O I
10.1021/ac991021i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric sensor for the detection of pyruvate in biological fluids was formed by modifying the tip of a 0.25-mm gold wire with a layer of electrically "wired" recombinant pyruvate oxidase (POP). The sensor did not require O-2 for its operation. The electroactive area of the tip of the microwire was increased by electrodeposition of platinum black. The POP was adsorbed on the platinum black and then "wired" with the cross-linked, subsequently deposited poly(4-vinylpyridine), part of the pyridine functions of which were complexed with [Os(bpy)(2)Cl](+/2+) and part quaternized with 8-bromoethyl-amine, In the resulting thin layer the POP was well "wired". When the electrode was poised at 0.4 V vs Ag/AgCl, the sensitivity at pH 6 was 0.26 A cm(-2) M-1 and the current increased linearly with the pyruvate concentration through the 2 x 10(-6)-6 x 10(-4) M range. Thiamine diphosphate, flavin adenine dinucleotide, and MgCl2 were not required for the assay, but stabilized the stored enzyme electrode. Placement of a dialysis membrane (MWCO 3500) on the electrode alleviated the severe interference of ascorbate, In calf serum, the detection limit was 30 mu M, suggesting that the electrode might be used in the continuous monitoring of pyruvate in hypoxic organs.
引用
收藏
页码:2963 / 2968
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 1984, GEIGY SCI TABLES
[2]   Pyruvate sensor based on pyruvate oxidase immobilized in a poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Noma, T ;
Habu, H ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (02) :143-148
[3]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131
[4]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[5]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[6]   REDOX POLYMER-FILMS CONTAINING ENZYMES .2. GLUCOSE-OXIDASE CONTAINING ENZYME ELECTRODES [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5976-5980
[7]  
GREILING H, 1989, LEHRBUCH KLINISCHEN
[8]   A novel biosensor system for the determination of phosphate [J].
Ikebukuro, K ;
Nishida, R ;
Yamamoto, H ;
Arikawa, Y ;
Nakamura, H ;
Suzuki, M ;
Kubo, I ;
Takeuchi, T ;
Karube, I .
JOURNAL OF BIOTECHNOLOGY, 1996, 48 (1-2) :67-72
[9]   ELECTROSTATIC CONTROL OF THE ELECTRON-TRANSFER ENABLING BINDING OF RECOMBINANT GLUCOSE-OXIDASE AND REDOX POLYELECTROLYTES [J].
KATAKIS, I ;
YE, L ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (08) :3617-3618
[10]  
KATAKIS I, 1996, ADV MOL CELL BIOL B, V15, P391