The evaluation procedure of a new laser-cooled caesium fountain primary frequency standard developed at the National Institute of Standards and Technology (NIST) is described. The new standard, NIST-F1, is described in some detail and typical operational parameters are discussed. Systematic frequency biases for which corrections are made - second-order Zeeman shift, black-body radiation shift, gravitational red shift and spin-exchange shift are discussed in detail. Numerous other frequency shifts are evaluated, but are so small in this type of standard that corrections are not made for their effects. We also discuss comparisons of this standard both with local frequency standards and with standards at other national laboratories.
引用
收藏
页码:321 / 336
页数:16
相关论文
共 29 条
[11]   DIRECT OBSERVATION OF S-WAVE ATOMIC-COLLISIONS [J].
GIBBLE, K ;
CHANG, S ;
LEGERE, R .
PHYSICAL REVIEW LETTERS, 1995, 75 (14) :2666-2669
[12]  
ITANO WD, 1982, PHYS REV A, V45, P1233
[13]   NIST cesium fountain microwave cavities [J].
Jefferts, SR ;
Drullinger, RE ;
DeMarchi, A .
PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, :6-8
[14]  
LARUENT P, 1999, P JOINT M EUR FREUQ, P152
[15]  
Leo PJ, 2001, PHYS REV LETT, V86, P3743, DOI 10.1103/PhysRevLett86.3743
[16]   Introduction to the special issue on the Dick effect [J].
Maleki, L .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :876-876
[17]  
Nava JFG, 1996, PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), P973, DOI 10.1109/FREQ.1996.560283
[18]  
Parker T. E., 1999, Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313), P173, DOI 10.1109/FREQ.1999.840736
[19]   Environmental factors and hydrogen maser frequency stability [J].
Parker, TE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (03) :745-751
[20]   Comparing and evaluating the perfomance of primary frequency standards: Impact of dead time [J].
Parker, TE .
PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, :57-62