The effect of joint loading on acetabular wear measurement in total hip arthroplasty

被引:31
作者
Martell, JM [1 ]
Leopold, SS [1 ]
Liu, XL [1 ]
机构
[1] Univ Chicago Hosp, Sect Orthopaed Surg & Rehabil Med, Chicago, IL 60637 USA
关键词
joint loading; acetabular wear; polyethylene wear; total hip arthroplasty;
D O I
10.1054/arth.2000.4336
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
All radiographic calculations of acetabular wear assume concentric reduction of the prosthetic articulation. To date, no studies have shown thar the femoral head is fully reduced on standard radiographs, and we have seen cases on early postoperative radiographs in which this assumption is not met. Using our computerized radiographic technique, 78 paired anteroposterior pelvic radiographs in 46 patients at a mean of 14 months after surgery (range, 1-92 months) were evaluated with and without joint loading. Displacement with loading was analyzed against time since surgery, a surrogate for acetabular wear. Regression analysis found a statistically significant increase in femoral head displacement after loading with longer duration of follow-up, but the rate of this increase was small (0.027 mm/y). This difference affects calculated wear values by <15%, We conclude that in a low-wear cohort, joint loading does not affect radiographic calculations of acetabular polyethylene wear in a clinically important way.
引用
收藏
页码:512 / 518
页数:7
相关论文
共 28 条
[1]
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]
APPEL AM, 1990, BRIT J RHEUMATOL, V29, P32
[3]
Bankston A B, 1993, J Arthroplasty, V8, P315
[4]
BARTEL DL, 1983, HIP
[5]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[6]
Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[7]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P303
[8]
MEASUREMENT OF HIP PROSTHESES USING IMAGE-ANALYSIS - THE MAXIMA HIP TECHNIQUE [J].
HARDINGE, K ;
PORTER, ML ;
JONES, PR ;
HUKINS, DWL ;
TAYLOR, CJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :724-728
[9]
HERNANDEZ JR, 1994, J BONE JOINT SURG BR, V76B, P263
[10]
A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES [J].
HOWIE, DW ;
VERNONROBERTS, B ;
OAKESHOTT, R ;
MANTHEY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :257-263