Selectivity tuning in chiral dual column gas chromatography

被引:12
作者
Krupcík, J
Spánik, I
Benická, E
Zabka, M
Welsch, T
Armstrong, DW
机构
[1] Slovak Univ Technol Bratislava, Fac Chem Technol, Dept Analyt Chem, Bratislava 81237, Slovakia
[2] Univ Ulm, Dept Analyt & Environm Chem, D-89069 Ulm, Germany
[3] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
关键词
D O I
10.1093/chromsci/40.9.483
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enantioselective tuning of two columns coupled in series is investigated in chiral high-resolution gas chromatography. Two columns with opposite enantioselectivities (Chirasil-L-Val and Chirasil-D-Val) are coupled in series via a T connector, and the relative retention of enantiomers chromatographed on the system is changed by varying the individual carrier gas flow rates in the coupled columns. The flow-rate ratio necessary for the required selectivity is calculated on the basis of the measured retention factors on the individual columns. The performance of this method for adjusting selectivity is studied by the separation of enantiomers of the N-TFA-O-methyl esters of six amino acids. It is demonstrated that the change of the coupling point carrier gas pressure, at the constant inlet and outlet pressures, may change the enantioselectivity of the given column series to such an extent that the enantiomer elution order may be reversed.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 12 条
[1]   Retention behavior of N-TFA-O-alkyl derivatives of selected amino acid enantiomers separated on modified cyclodextrins by HRGC [J].
Benicka, E ;
Krupcik, J ;
Spanik, I ;
Hrouzek, J ;
Sandra, P .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1996, 8 (01) :57-65
[2]   THRESHOLD CRITERIA USED FOR THE OPTIMIZATION OF SELECTIVITY BY TUNING INTERMEDIATE PRESSURE FOR SERIES-COUPLED COLUMNS IN A DUAL-OVEN SYSTEM [J].
BENICKA, E ;
KRUPCIK, J ;
REPKA, D ;
KULJOVSKY, P ;
KAISER, RE .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :985-990
[3]  
Cortes HJ, 1990, MULTIDIMENSIONAL CHR
[4]   CHIRAL POLYSILOXANES FOR RESOLUTION OF OPTICAL-ANTIPODES [J].
FRANK, H ;
GRAEME, JN ;
BAYER, E .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1978, 17 (05) :363-365
[5]   RAPID GAS-CHROMATOGRAPHIC SEPARATION OF AMINO-ACID ENANTIOMERS WITH A NOVEL CHIRAL STATIONARY PHASE [J].
FRANK, H ;
NICHOLSON, GJ ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (05) :174-176
[6]  
Frank H., 1978, ANGEW CHEM, V90, P396
[7]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .1. FUNDAMENTAL RELATIONSHIPS [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (10) :561-572
[8]  
KAISER RE, 1979, HRC-J HIGH RES CHROM, V2, P416
[9]   Computerized optimization of selectivity for direct capillary gas chromatographic multicomponent separations of enantiomers [J].
Krupcik, J ;
Grena, M ;
Spanik, I ;
Benicka, E ;
Hrouzek, J ;
Skacani, I ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :253-262
[10]   MEASUREMENT OF RETENTION DATA ON OPEN TUBULAR COLUMNS COUPLED IN SERIES [J].
KRUPCIK, J ;
GUIOCHON, G ;
SCHMITTER, JM .
JOURNAL OF CHROMATOGRAPHY, 1981, 213 (02) :189-201