Improvement of measurement precision of SPME-GC/MS determination of tributyltin using isotope dilution calibration

被引:37
作者
Bancon-Montigny, C [1 ]
Maxwell, P [1 ]
Yang, L [1 ]
Mester, Z [1 ]
Sturgeon, RE [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1021/ac0258002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A unique approach was developed to improve the precision of quantification of tributyltin (TBT) in sediments by solid phase microextraction (SPME) using isotope dilution GC/MS. The precision of the analytical technique was initially evaluated using standard calibration solutions. In selective ion monitoring (SIM) mode, the relative standard deviation (RSD) obtained for TBT based on peak area response was 18% (n = 11). When an internal standard, tripropyltin (TPrT), was used, the RSD decreased to 12%. A significant improvement in the precision using SPME was noted when a Sn-117-enriched TBT spike was employed; the RSD decreased 4-fold to 3%. Detection limits of 0.2 and 20 ng(Sn) L-1 were achieved with SPME sampling and liquid-liquid extraction, respectively. Six analyses were performed for determination of TBT in PACS-2 sediment Certified Reference Material using both standard additions and isotope dilution procedures. For the latter, a Sn-117-enriched TBT spike was used. A concentration of 0.88 +/- 0.03 mug g(-1)(RSD 3.4%) obtained using standard additions was in good agreement with the certified value of 0.98 +/- 0.13 mug g(-1) as tin. Concentrations found using isotope dilution were 0.895 +/- 0.015 mug g(-1) (RSD 1.73%) as tin and 0.874 +/- 0.014 mug g(-1) (RSD 1.66%) as tin using a liquid-liquid extraction and SPME sampling, respectively. A 2-fold improvement in the precision of TBT concentration measurement using isotope dilution was clearly achieved, demonstrating its superiority in providing more accurate and precise results as compared to the method of standard additions. The isotope dilution technique eliminated the problem of poor reproducibility, which typically plagues SPME.
引用
收藏
页码:5606 / 5613
页数:8
相关论文
共 57 条
  • [51] Tutschku S, 1996, FRESEN J ANAL CHEM, V354, P587
  • [52] Headspace solid-phase microextraction-capillary gas chromatography-ICP mass spectrometry for the determination of the organotin pesticide fentin in environmental samples
    Vercauteren, J
    De Meester, A
    De Smaele, T
    Vanhaecke, F
    Moens, L
    Dams, R
    Sandra, P
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 651 - 656
  • [53] Selenomethionine content of candidate reference materials
    Wolf, WR
    Zainal, H
    Yager, B
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (2-3): : 286 - 290
  • [54] Determination of tributyltin by automated in-tube solid-phase microextraction coupled with HPLC-ES-MS
    Wu, JC
    Mester, Z
    Pawliszyn, J
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (02) : 159 - 165
  • [55] Organotin compounds and polychlorinated biphenyls of livers in squid collected from coastal waters and open oceans
    Yamada, H
    Takayanagi, K
    Tateishi, M
    Tagata, H
    Ikeda, K
    [J]. ENVIRONMENTAL POLLUTION, 1997, 96 (02) : 217 - 226
  • [56] Species-specific isotope dilution-based calibration for trace element speciation and its combined uncertainty evaluation: Determination of tributyltin in sediment by HPLC-ICPMS
    Yang, L
    Mester, Z
    Sturgeon, RE
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (13) : 2968 - 2976
  • [57] Improvement in measurement precision with SPME by use of isotope dilution mass spectrometry and its application to the determination of tributyltin in sediment using SPME GC-ICP-MS
    Yang, L
    Mester, Z
    Sturgeon, RE
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 944 - 949