Kelvin probe force microscopy in ultra high vacuum using amplitude modulation detection of the electrostatic forces

被引:98
作者
Sommerhalter, C [1 ]
Glatzel, T [1 ]
Matthes, TW [1 ]
Jäger-Waldau, A [1 ]
Lux-Steiner, MC [1 ]
机构
[1] Hahn Meitner Inst Kernforsch Berlin GmbH, D-14109 Berlin, Germany
关键词
Kelvin probe; UHV; AFM; EFM; contact potential difference; work function;
D O I
10.1016/S0169-4332(99)00537-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We present a detailed study of contact potential difference measurements in ultra high vacuum using Kelvin probe force microscopy. A dependence of the contact potential difference on the tip-sample distance was measured and is explained by an inhomogeneous work function of the highly doped silicon cantilever. On semiconducting samples the measured contact potential difference additionally depends on the AC sample voltage. By investigating this effect for different AC voltages and tip-sample distances, we can conclude that bias-induced bandbending has to be considered in a quantitative analysis of the contact potential difference on semiconductors. Using amplitude modulation detection of the electrostatic forces at the second resonance frequency, a high sensitivity can be achieved at low AC voltages. Spatially resolved contact potential difference measurements on submonolayer fullerene islands grown on graphite were used to determine the lateral resolution of approximately 20 nm. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 15 条
[1]   FREQUENCY-MODULATION DETECTION USING HIGH-Q CANTILEVERS FOR ENHANCED FORCE MICROSCOPE SENSITIVITY [J].
ALBRECHT, TR ;
GRUTTER, P ;
HORNE, D ;
RUGAR, D .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (02) :668-673
[2]   Electrostatic forces acting on the tip in atomic force microscopy: Modelization and comparison with analytic expressions [J].
Belaidi, S ;
Girard, P ;
Leveque, G .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (03) :1023-1030
[3]  
BOHMISCH M, 1998, THESIS KONSTANZ GERM
[4]   2-DIMENSIONAL SURFACE DOPANT PROFILING IN SILICON USING SCANNING KELVIN PROBE MICROSCOPY [J].
HENNING, AK ;
HOCHWITZ, T ;
SLINKMAN, J ;
NEVER, J ;
HOFFMANN, S ;
KASZUBA, P ;
DAGHLIAN, C .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (05) :1888-1896
[5]   Capacitive effects on quantitative dopant profiling with scanned electrostatic force microscopes [J].
Hochwitz, T ;
Henning, AK ;
Levey, C ;
Daghlian, C ;
Slinkman, J .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (01) :457-462
[6]   ELECTROSTATIC FORCES BETWEEN METALLIC TIP AND SEMICONDUCTOR SURFACES [J].
HUDLET, S ;
SAINTJEAN, M ;
ROULET, B ;
BERGER, J ;
GUTHMANN, C .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (07) :3308-3314
[7]   Practical aspects of Kelvin probe force microscopy [J].
Jacobs, HO ;
Knapp, HF ;
Stemmer, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03) :1756-1760
[8]   Resolution and contrast in Kelvin probe force microscopy [J].
Jacobs, HO ;
Leuchtmann, P ;
Homan, OJ ;
Stemmer, A .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (03) :1168-1173
[9]   SILICON PN JUNCTION IMAGING AND CHARACTERIZATIONS USING SENSITIVITY ENHANCED KELVIN PROBE FORCE MICROSCOPY [J].
KIKUKAWA, A ;
HOSAKA, S ;
IMURA, R .
APPLIED PHYSICS LETTERS, 1995, 66 (25) :3510-3512
[10]   Vacuum compatible high-sensitive Kelvin probe force microscopy [J].
Kikukawa, A ;
Hosaka, S ;
Imura, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (04) :1463-1467