Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction

被引:96
作者
Ali, Iftikhar [1 ]
Ruddy, Terrence D. [1 ,2 ]
Almgrahi, Abdulaziz [1 ]
Anstett, Frank G. [3 ]
Wells, R. Glenn [1 ,2 ]
机构
[1] Univ Ottawa, Div Cardiol, Inst Heart, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Ottawa Hosp, Div Nucl Med, Ottawa, ON K1Y 4W7, Canada
[3] GE Healthcare, Waukesha, WI USA
关键词
SPECT; myocardial perfusion imaging; resolution recovery; attenuation correction; GEOMETRIC TRANSFER-FUNCTION; RECONSTRUCTION; COMPENSATION; COLLIMATORS;
D O I
10.2967/jnumed.108.058362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Reducing acquisition time may improve patient throughput, increase camera efficiency, and reduce costs; reducing acquisition time also increases image noise. Newly available software controls the effects of noise by maximum a posteriori reconstruction while maintaining resolution with resolution-recovery methods. This study compares half-time (HT) gated myocardial SPECT images processed with ordered-subset expectation maximization with resolution recovery (OSEM-RR) (with and without CT-based attenuation correction [AC]) with full-time (FT) images obtained with a standard clinical protocol and reconstructed with filtered backprojection (FBP) and OSEM(with and without AC). Methods: A total of 212 patients (mean age, 57 y; age range, 27-86 y) underwent 1-d rest/stress Tc-99m-tetrofosmin gated SPECT. FT (12.5 min, both rest and stress) and HT (rest, 7.5 min; stress, 6.0 min) images were acquired with low-dose CT for AC in 112 patients. HT acquisitions were processed with OSEM-RR( with and without AC) using software, and FT acquisitions were processed with FBP and OSEM (with and without AC). In another 100 patients, test-retest repeatability was assessed using 2 sets of FT images (FBP reconstruction) that were acquired one immediately after the other. Radiologists unaware of the acquisition and reconstruction protocols visually assessed all reconstructed images for summed stress, summed rest, and summed difference scores and regional wall motion using a 17-segment model. Automated analysis on gated SPECT was used to determine left ventricular volumes, ejection fraction, and dilation (end-diastolic volume, end-systolic volume, left ventricular ejection fraction, and transient ischemic dilation [TID]). A clinical diagnosis was also determined. Results: All measurements resulted in significant correlations (P < 0.01) between the HT and FT images. The only significant difference in mean values was for OSEM-RR plus AC; this method led to an increase in TID by 4% over FT imaging. The concordance in the clinical diagnosis for HT versus FT was 106 to 112 (kappa = 0.88) for no AC and 102 to 106 (kappa = 0.91) for AC, similar to the repeatability of FT versus FT (98/100, kappa = 0.95). Conclusion: HT images processed with the new algorithm provided a clinical diagnosis in concordance with that from FT images in 95%(no AC) to 96%(AC) of cases. This concordance is similar to the test-retest repeatability of FT imaging.
引用
收藏
页码:554 / 562
页数:9
相关论文
共 27 条
[1]
Transient ischemic dilation ratio of the left ventricle is a significant predictor of future cardiac events in patients with otherwise normal myocardial perfusion SPECT [J].
Abidov, A ;
Bax, JJ ;
Hayes, SW ;
Hachamovitch, R ;
Cohen, I ;
Gerlach, J ;
Kang, XP ;
Friedman, JD ;
Germano, G ;
Berman, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (10) :1818-1825
[2]
Bayesian image reconstruction for emission tomography based on median root prior [J].
Alenius, S ;
Ruotsalainen, U .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) :258-265
[3]
BATEMAN TM, ASNC 2007 M SEPT 6 9
[4]
BELHOCINE T, 2007, J NUCL MED S, V48, pP234
[5]
Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies [J].
Borges-Neto, Salvador ;
Pagnanelli, Robert A. ;
Shaw, Linda K. ;
Honeycutt, Emily ;
Shwartz, Shuli C. ;
Adams, George L. ;
Coleman, Ralph Edward .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :555-565
[6]
DEPUEY E, 1995, J NUCL MED, V36, P952
[7]
Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection [J].
DePuey, E. Gordon ;
Gadiraju, Ramesh ;
Clark, John ;
Thompson, Linda ;
Anstett, Frank ;
Shwartz, Shuli C. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (04) :547-563
[8]
DEPUEY EG, 1995, J NUCL MED, V36, P569
[9]
DEPUEY G, 2007, J NUCL MED S, V48, pP237
[10]
DEPUEY G, 2007, P ICNC M MAY 2 PRAG