Bone Remodeling Characteristics of a Short-Stemmed Total Hip Replacement

被引:110
作者
Chen, Hsiang-Ho [2 ]
Morrey, Bernard F. [3 ]
An, Kai-Nan [3 ]
Luo, Zong-Ping [1 ]
机构
[1] Florida Orthopaed Inst, Tampa, FL 33637 USA
[2] Taipei Med Univ, Dept Physiol, Taipei, Taiwan
[3] Mayo Clin, Dept Orthopaed, Rochester, MN USA
关键词
short-stemmed; femur; arthroplasty; bone remodeling; follow-up; X-RAY ABSORPTIOMETRY; PERIPROSTHETIC BONE; FEMORAL COMPONENTS; MINERAL DENSITY; ARTHROPLASTY; PROSTHESIS; BEHAVIOR; FEMUR; ESKA;
D O I
10.1016/j.arth.2008.07.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Bone remodeling of a metaphyseal fixed femoral stem, Mayo Conservative Hip (Zimmer International, Warsaw, Ind), was characterized by the dual-energy x-ray absorptiometry and a mathematical remodeling model. The mean age of the patient was 50.8 years, and the mean follow-up was 5.7 years. As anticipated, bony structure underwent significant remodeling after the short-stemmed femoral arthroplasty with resorption proximally and ingrowth distally/laterally. Theoretical prediction further Suggested that the remodeling was largely regulated by the mechanical loading distribution pattern determined by implant design.
引用
收藏
页码:945 / 950
页数:6
相关论文
共 33 条
[1]
[Anonymous], 1979, Clin Orthop Relat Res
[2]
Alendronate prevents femoral periprosthetic bone loss following total hip arthroplasty: Prospective randomized double-blind study [J].
Arabmotlagh, Mohammad ;
Rittmeister, Markus ;
Hennigs, Thorsten .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (07) :1336-1341
[3]
AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - APPLICATION - A PRELIMINARY REMODELING SIMULATION [J].
BEAUPRE, GS ;
ORR, TE ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :662-670
[4]
Continuous bone loss around a tapered uncemented femoral stem -: A long-term evaluation with DEXA [J].
Boden, Henrik S. G. ;
Skoldenberg, Olof G. ;
Salemyr, Mats F. ;
Lundberg, Hans-Jerker ;
Adolphson, Per Y. .
ACTA ORTHOPAEDICA, 2006, 77 (06) :877-885
[5]
Radiological findings and clinical results of 102 thrust-plate femoral hip prostheses - A follow-up of 2 to 8 years [J].
Buergi, ML ;
Stoffel, KK ;
Jacob, HAC ;
Bereiter, HH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :108-117
[6]
COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[7]
INFLUENCE OF DESIGN PARAMETERS ON CALCAR STRESSES FOLLOWING FEMORAL-HEAD ARTHROPLASTY [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (02) :133-143
[8]
Bone loss after total hip arthroplasty [J].
Dan, Diana ;
Germann, David ;
Burki, Hubert ;
Hausner, Peter ;
Kappeler, Urs ;
Meyer, Rainer Peter ;
Klaghofer, Richard ;
Stoll, Thomas .
RHEUMATOLOGY INTERNATIONAL, 2006, 26 (09) :792-798
[9]
Clinical consequences of stress shielding after porous-coated total hip arthroplasty [J].
Engh, CA ;
Young, AM ;
Engh, CA ;
Hopper, RH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :157-163
[10]
Short- and medium-term results of the thrust plate prosthesis in patients with polyarthritis [J].
Fink, B ;
Siegmüller, C ;
Schneider, T ;
Conrad, S ;
Schmielau, G ;
Rüther, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (5-6) :294-298