Evaluation of the catheter positioning for neurally adjusted ventilatory assist

被引:91
作者
Barwing, Jurgen [1 ]
Ambold, Markus [1 ]
Linden, Nadine [1 ]
Quintel, Michael [1 ]
Moerer, Onnen [1 ]
机构
[1] Univ Gottingen, Dept Anaesthesiol, D-37075 Gottingen, Germany
关键词
Neurally adjusted ventilatory assist (NAVA); Neural control; Electrical activation of the diaphragm (EAdi); BARDET-BIEDL-SYNDROME; MECHANICAL VENTILATION; SYNCHRONY; DIAPHRAGM; RABBITS;
D O I
10.1007/s00134-009-1587-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
During neurally adjusted ventilatory assist (NAVA) the ventilator is driven by the patients electrical activation of the diaphragm (EAdi), detected by a special esophageal catheter. A reliable positioning of the EAdi-catheter is mandatory to trace a representative EAdi signal. We aimed to determine whether a formula that is based on the measurement from nose to ear lobe to xiphoid process of the sternum (NEX distance) modified for EAdi-catheter placement (NEXmod) is sufficient for predicting the accurate catheter position. Twenty-six patients were enrolled in this study. The optimal EAdi-catheter position (OPT) was defined by: (1) stable EAdi signal, (2) electrical activity highlighted in central leads of the catheter positioning tool, and (3) absence of p-wave in distal lead. Afterwards NEXmod was calculated and compared to the OPT finding. At NEXmod the EAdi signal was suitable for running NAVA in 18 out of 25 patients (72%). NEXmod was identical with OPT in four patients (16%). NAVA was possible in all patients at OPT. Median OPT position was 2 cm caudal of the NEXmod ranging from 3 cm too cranial to a position 12 cm too caudal (P < 0.01). In one patient excluded from further analysis EAdi-catheter placement led to the diagnosis of bilateral injury of the phrenic nerves. EAdi-catheter placement based on the NEXmod formula allows running NAVA in about two-thirds of all patients. The additional tools provided are efficient and facilitate the correct positioning of the EAdi-catheter for neurally adjusted ventilatory assist.
引用
收藏
页码:1809 / 1814
页数:6
相关论文
共 16 条
[1]   Influence of neurally adjusted ventilatory assist and positive end-expiratory pressure on breathing pattern in rabbits with acute lung injury [J].
Allo, Jean-Christophe ;
Beck, Jennifer C. ;
Brander, Lukas ;
Brunet, Fabrice ;
Slutsky, Arthur S. ;
Sinderby, Christer A. .
CRITICAL CARE MEDICINE, 2006, 34 (12) :2997-3004
[2]   Influence of bipolar esophageal electrode positioning on measurements of human crural diaphragm electromyogram [J].
Beck, J ;
Sinderby, C ;
Lindstrom, L ;
Grassino, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (03) :1434-1449
[3]   Improved synchrony and respiratory unloading by neurally adjusted ventilatory assist (NAVA) in lung-injured rabbits [J].
Beck, Jennifer ;
Campoccia, Francesca ;
Allo, Jean-Christophe ;
Brander, Lukas ;
Brunet, Fabrice ;
Slutsky, Arthur S. ;
Sinderby, Christer .
PEDIATRIC RESEARCH, 2007, 61 (03) :289-294
[4]  
Bland JM, 1986, LANCET, Vi, P307
[5]   Titration and Implementation of Neurally Adjusted Ventilatory Assist in Critically III Patients [J].
Brander, Lttkas ;
Leong-Poi, Howard ;
Beck, Jermifer ;
Brunet, Fabrice ;
Hutchison, Stuart J. ;
Slutsky, Arthur S. ;
Sinderby, Christe .
CHEST, 2009, 135 (03) :695-703
[6]   Physiologic response to varying levels of pressure support and neurally adjusted ventilatory assist in patients with acute respiratory failure [J].
Colombo, Davide ;
Cammarota, Gianmaria ;
Bergamaschi, Valentina ;
De Lucia, Marta ;
Della Corte, Francesco ;
Navalesi, Paolo .
INTENSIVE CARE MEDICINE, 2008, 34 (11) :2010-2018
[7]   THE CRURA OF THE DIAPHRAGM AND DIAPHRAGMATIC PASSAGE - APPLICATIONS TO GASTROESOPHAGEAL REFLUX, ITS INVESTIGATION AND TREATMENT [J].
DELATTRE, JF ;
PALOT, JP ;
DUCASSE, A ;
FLAMENT, JB ;
HUREAU, J .
ANATOMIA CLINICA, 1985, 7 (04) :271-283
[8]   EFFECTS OF ANESTHESIA AND PARALYSIS ON DIAPHRAGMATIC MECHANICS IN MAN [J].
FROESE, AB ;
BRYAN, AC .
ANESTHESIOLOGY, 1974, 41 (03) :242-255
[10]  
KRANKE B, 1993, MED KLIN, V88, P78