Evaluation of direct stent implantation without predilatation by intravascular ultrasound

被引:13
作者
Hernandez, JMD [1 ]
Gomez, I [1 ]
Rodriguez-Entem, F [1 ]
Zueco, J [1 ]
Figueroa, A [1 ]
Colman, T [1 ]
机构
[1] Hosp Univ Marques Valdecilla, Unidad Hemodinam, Dept Intervent Cardiol, Santander 39008, Spain
关键词
D O I
10.1016/S0002-9149(99)00926-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present study shows that direct stent implantation without predilatation in selected lesions provides angiographic and ultrasonographic results that could be comparable to those expected with conventional stenting. These results may even safely improve if a balloon/artery ratio of 1.1 to 1.2 is used in combination with implantation pressures of 12 to 16 atm.
引用
收藏
页码:1028 / +
页数:4
相关论文
共 10 条
[1]   Mechanisms of residual lumen stenosis after high-pressure stent implantation -: A quantitative coronary angiography and intravascular ultrasound study [J].
Bermejo, J ;
Botas, J ;
García, E ;
Elízaga, J ;
Osende, J ;
Soriano, J ;
Abeytua, M ;
Delcán, JL .
CIRCULATION, 1998, 98 (02) :112-118
[2]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[3]  
Figulla HR, 1998, CATHETER CARDIO DIAG, V43, P245, DOI 10.1002/(SICI)1097-0304(199803)43:3<245::AID-CCD1>3.0.CO
[4]  
2-9
[5]  
Hernández JMD, 1999, REV ESP CARDIOL, V52, P301
[6]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[7]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49
[8]  
Kearney PP, 1997, CATHETER CARDIO DIAG, V40, P1
[9]   Direct stent implantation without predilation using the multilink stent [J].
Pentousis, D ;
Guérin, Y ;
Funck, F ;
Zheng, H ;
Toussaint, M ;
Corcos, T ;
Favereau, X .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (12) :1437-1440
[10]   Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: A multicenter, randomized study comparing two strategies - With and without intravascular ultrasound guidance [J].
Schiele, F ;
Meneveau, N ;
Vuillemenot, A ;
Zhang, DD ;
Gupta, S ;
Mercier, M ;
Danchin, N ;
Bertrand, B ;
Bassand, JP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (02) :320-328