Influence of the Real Background Signal on the Linearity of the Stern-Volmer Calibration for the Determination of Molecular Oxygen with Optical Sensors

被引:12
作者
Badocco, Denis [1 ]
Mondin, Andrea [1 ]
Fusar, Alberto [1 ]
Favaro, Gabriella [1 ]
Pastore, Paolo [1 ]
机构
[1] Univ Padua, Dept Chem Sci, I-35131 Padua, Italy
关键词
LUMINESCENCE; COMPLEXES; PLATINUM; FILMS; DYES;
D O I
10.1021/jp9050676
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The role of light emission components unrelated to the Stern-Volmer (SV) kinetic model, in the curvature of the Stern-Volmer model, was evidenced and the discrepancy often encountered between calibrations with light intensity, 1, and luminescence lifetime,tau, was explained by means of mathematical models applied to experimental data. Sensing membranes prepared embedding tris-4,7-diphenyl-1,10-phenanthroline (Ru(dpp)), platinum(H) meso-tetraphenylporphyrin (PtTPP), and palladium(II) meso-tetra(pentafluorophenyl)porphyrin (PdFTPP) in a polysulfone matrix were used to confirm the proposed theory. Multisite hypotheses or other correction procedures must be invoked only after a careful evaluation of the background light really present in the system. A new form of the SV equation having the advantage to obtain the K-SV' and the effective background with a simple unweighted regression method was proposed and compared to the "classical" SV requiring the knowledge of the background and a weighted regression. Experimental results confirmed the theory for what concerns the concentration limit for the determination of oxygen which may be theoretically determined. Ru(dpp)OS, PtTPP, and PdFTPP membranes may determine oxygen mixtures up to 100, 60.7, and 19.0%, respectively, with a resolution of 2%. Narrower working intervals are explorable if better resolution is required.
引用
收藏
页码:15742 / 15750
页数:9
相关论文
共 38 条
[21]   Fast response oxygen micro-optodes based on novel soluble ormosil glasses [J].
Klimant, I ;
Ruckruh, F ;
Liebsch, G ;
Stangelmayer, C ;
Wolfbeis, OS .
MIKROCHIMICA ACTA, 1999, 131 (1-2) :35-46
[22]   Electronic spectroscopy, photophysical properties, and emission quenching studies of an oxidatively robust perfluorinated platinum porphyrin [J].
Lai, SW ;
Hou, YJ ;
Che, CM ;
Pang, HL ;
Wong, KY ;
Chang, CK ;
Zhu, NY .
INORGANIC CHEMISTRY, 2004, 43 (12) :3724-3732
[23]   A statistical overview on univariate calibration, inverse regression, and detection limits: Application to gas chromatography/mass spectrometry technique [J].
Lavagnini, Irma ;
Magno, Franco .
MASS SPECTROMETRY REVIEWS, 2007, 26 (01) :1-18
[24]   Temperature compensation of fluorescence intensity-based fiber-optic oxygen sensors using modified Stern-Volmer model [J].
Lo, Yu-Lung ;
Chu, Chen-Shane ;
Yur, Jiahn-Piring ;
Chang, Yuan-Che .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02) :479-488
[25]   Characterizing the quenching process for phosphorescent dyes in poly[((n-butylamino)thionyl)phosphazene] films [J].
Lu, X ;
Han, BH ;
Winnik, MA .
JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (48) :13349-13356
[26]  
Malinski T., 2000, PORPHYRIN HDB, V6, P231
[27]   An overview of model-robust regression [J].
Mays, JE ;
Birch, JB ;
Einsporn, RL .
JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2000, 66 (01) :79-100
[28]   Phase fluorometric dissolved oxygen sensor [J].
McDonagh, C ;
Kolle, C ;
McEvoy, AK ;
Dowling, DL ;
Cafolla, AA ;
Cullen, SJ ;
MacCraith, BD .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :124-130
[29]   Response characteristics of optical sensors for oxygen:: a model based on a distribution in τo and κq [J].
Mills, A .
ANALYST, 1999, 124 (09) :1309-1314
[30]   Optical sensors for oxygen: a log-gaussian multisite-quenching model [J].
Mills, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :69-76