Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee

被引:200
作者
Hafner, Brian J. [1 ]
Willingham, Laura L. [1 ]
Buell, Noelle C. [1 ]
Allyn, Katheryn J. [1 ]
Smith, Douglas G. [1 ]
机构
[1] Prosthet Res Study, Seattle, WA 98104 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2007年 / 88卷 / 02期
关键词
amputees; artificial limbs; knee; patient satisfaction; rehabilitation;
D O I
10.1016/j.apmr.2006.10.030
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To evaluate differences in function, performance, and preference between mechanical and microprocessor prosthetic knee control technologies. Design: A-B-A-B reversal design. Setting: Home, community, and laboratory environments. Participants: Twenty-one unilateral, transfemoral amputees. Intervention: Mechanical control prosthetic knee versus microprocessor control prosthetic knee (Otto Bock C-Leg). Main Outcome Measures: Stair rating, hill rating and time, obstacle course time, divided attention task accuracy and time, Amputee Mobility Predictor score, step activity, Prosthesis Evaluation Questionnaire score, Medical Outcomes Study 36-Item Short-Form Health Survey score, self-reported frequency of stumbles and falls, and self-reported concentration required for ambulation. Results: Stair descent score, hill descent time, and hill sound-side step length showed significant (P <.01) improvement with the C-Leg. Users reported a significant (P <.05) decrease in frequency of stumbles and falls, frustration with falling, and difficulty in multitasking while using the microprocessor knee. Subject satisfaction with the C-Leg was significantly (P <.001) greater than the mechanical control prosthesis. Conclusions: The study population showed improved performance when negotiating stairs and hills, reduced frequency of stumbling and falling, and a preference for the microprocessor control C-Leg as compared with the mechanical control prosthetic knee.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 19 条
  • [1] Energy cost of walking: Comparison of ''Intelligent prosthesis'' with conventional mechanism
    Buckley, JG
    Spence, WD
    Solomonidis, SE
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (03): : 330 - 333
  • [2] Buell N. C., 2004, PROC 11 WORLD C INT, P53
  • [3] Buell N. C., 2004, PROC 11 WORLD C INT, P367
  • [4] Comparison of different microprocessor controlled knee joints on the energy consumption during walking in trans-femoral amputees: Intelligent Knee Prosthesis (IP) versus C-Leg
    Chin, T
    Machida, K
    Sawamura, S
    Shiba, R
    Oyabu, H
    Nagakura, Y
    Takase, I
    Nakagawa, A
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (01) : 73 - 80
  • [5] Energy expenditure during walking in amputees after disarticulation of the hip - A microprocessor-controlled swing-phase control knee versus a mechanical-controlled stance-phase control knee
    Chin, T
    Sawamura, S
    Shiba, R
    Oyabu, H
    Nagakura, Y
    Nakagawa, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (01): : 117 - 119
  • [6] Effect of an intelligent prosthesis (IP) on the walking ability of young transfemoral amputees - Comparison of IP users with able-bodied people
    Chin, T
    Sawamura, S
    Shiba, R
    Oyabu, H
    Nagakura, Y
    Takase, I
    Machida, K
    Nakagawa, A
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2003, 82 (06) : 447 - 451
  • [7] Datta D, 1998, PROSTHET ORTHOT INT, V22, P129
  • [8] A comparative evaluation of oxygen consumption and gait pattern in amputees using Intelligent Prostheses and conventionally damped knee swing-phase control
    Datta, D
    Heller, B
    Howitt, J
    [J]. CLINICAL REHABILITATION, 2005, 19 (04) : 398 - 403
  • [9] ENGLISH RD, 1995, J REHABIL RES DEV, V32, P32
  • [10] The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's ability to ambulate
    Gailey, RS
    Roach, KE
    Applegate, EB
    Cho, B
    Cunniffe, B
    Licht, S
    Maguire, M
    Nash, MS
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (05): : 613 - 627