Temperature effects on selectivity using carbon dioxide-based mobile phases on silica-based packed columns near the mixture critical point

被引:10
作者
Blackwell, JA
Stringham, RW
机构
[1] Dupont Merck Pharmaceutical Company, Chem. Proc. Research and Development, Chambers Works, Deepwater
关键词
supercritical fluid chromatography; packed columns; temperature vs. selectivity; hydrogen bonding of analytes;
D O I
10.1007/BF02466746
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The temperature dependence on selectivity using modified carbon dioxide mobile phases with silica-based packed columns is found to be primarily related to the hydrogen bonding character of the analytes. Selectivity between hydrogen bond acceptor compounds is enhanced at temperatures above the mixture critical temperature. Selectivity for these compounds is further enhanced using hydrogen bond donating modifiers, such as alcohols. Selectivity between hydrogen bond donor/acceptor compounds is enhanced at lower temperatures, below the mixture critical temperature, regardless of the modifier used. Analysis of the enthalpic contributions to retention indicate that the main driving force behind these variations in temperature and modifier effects are the differences in solute heat of adsorption on the silica stationary phase.
引用
收藏
页码:521 / 528
页数:8
相关论文
共 30 条
[21]   Addition of methanol to the mobile phase in packed capillary column supercritical fluid chromatography - Retention mechanisms from linear solvation energy relationships [J].
Pyo, D ;
Li, WB ;
Lee, ML ;
Weckwerth, JD ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :291-298
[22]   STUDY OF RETENTION PROCESSES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY THE USE OF THE SOLVATOCHROMIC COMPARISON METHOD [J].
SADEK, PC ;
CARR, PW ;
DOHERTY, RM ;
KAMLET, MJ ;
TAFT, RW ;
ABRAHAM, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2971-2978
[23]   SOLVATOCHROMICALLY BASED SOLVENT-SELECTIVITY TRIANGLE [J].
SNYDER, LR ;
CARR, PW ;
RUTAN, SC .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :537-547
[24]   ''Entropically driven'' chiral separations in supercritical fluid chromatography. Confirmation of isoelution temperature and reversal of elution order [J].
Stringham, RW ;
Blackwell, JA .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2179-2185
[25]   HIGH-PRESSURE PHASE DISTRIBUTION ISOTHERMS FOR SUPERCRITICAL FLUID CHROMATOGRAPHIC SYSTEMS .2. BINARY ISOTHERMS OF CARBON-DIOXIDE AND METHANOL [J].
STRUBINGER, JR ;
SONG, HC ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :104-108
[26]   HIGH-PRESSURE PHASE DISTRIBUTION ISOTHERMS FOR SUPERCRITICAL FLUID CHROMATOGRAPHIC SYSTEMS .1. PURE CARBON-DIOXIDE [J].
STRUBINGER, JR ;
SONG, HC ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :98-103
[27]  
WECKWERTH JD, 1996, THESIS U MINNESOTA
[28]   CORRELATION OF SOLVATOCHROMIC EFFECTS WITH RETENTION IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
YONKER, CR ;
GALE, RW ;
SMITH, RD .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :83-92
[29]   TEMPERATURE-DEPENDENCE OF RETENTION IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
YONKER, CR ;
WRIGHT, BW ;
PETERSEN, RC ;
SMITH, RD .
JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (25) :5526-5530
[30]  
1993, NIST THERMODYNAMIC P