Comparison of measured and calculated peripheral doses in patients undergoing radiation therapy

被引:19
作者
VanderGiessen, PH
Bierhuizen, HWJ
机构
[1] Dr. Bernard Verbeeten Inst. R., Department of Clinical Physics, Brugstraat 10
关键词
gonadal dose; peripheral dose; radiation therapy; risk assessment;
D O I
10.1016/S0167-8140(96)01885-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Many papers have been published on the measurement for specific treatment machines and/or techniques of the dose to points outside the primary beam, often called the peripheral dose (PD). Most papers concern measurements in phantoms. We report on the results of a comparison of estimates of the PD, based on these phantom measurements, with PDs measured on patients. Material and methods: A special holder with thermoluminescent dosimeters was placed against the perineum of patients referred to our institute for radiation therapy. The measured dose was then compared with the dose calculated on the basis of published PD data. Results: For all measurements together, the calculated values exceeded the measured PDs by about 9%, with a standard deviation of 35%. The correlation varied between specific subgroups but the difference between measurement and calculation did not exceed 50%. Conclusions: We conclude that published PD data can be used to accurately predict the peripheral dose in the clinical situation. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 24 条
[1]   TESTICULAR DOSES IN DEFINITIVE RADIATION-THERAPY FOR LOCALIZED PROSTATE-CANCER [J].
AMIES, CJ ;
MAMEGHAN, H ;
ROSE, A ;
FISHER, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (03) :839-846
[2]   ACCELERATOR ROOM PHOTO-NEUTRON AND PHOTON BACKGROUND MEASUREMENTS USING THERMOLUMINESCENT DOSIMETERS [J].
ANDERSON, DW ;
HWANG, CC .
HEALTH PHYSICS, 1983, 44 (02) :115-125
[3]  
CAMERON J. R., 1964, HLTH PHYS, V10, P25, DOI 10.1097/00004032-196401000-00003
[4]   Estimation of the radiation dose delivered to any point outside the target volume per patient treated with external beam radiotherapy [J].
Diallo, I ;
Lamon, A ;
Shamsaldin, A ;
Grimaud, E ;
deVathaire, F ;
Chavaudra, J .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (03) :269-271
[5]   PERIPHERAL DOSE FROM MEGAVOLT BEAMS [J].
FRAASS, BA ;
VANDEGEIJN, J .
MEDICAL PHYSICS, 1983, 10 (06) :809-818
[6]   PHOTONEUTRONS FROM MEDICAL LINEAR ACCELERATORS - RADIOBIOLOGICAL MEASUREMENTS AND RISK ESTIMATES [J].
HALL, EJ ;
MARTIN, SG ;
AMOLS, H ;
HEI, TK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (01) :225-230
[7]  
KARTHA P, 1978, MED PHYS, V5, P327
[8]   MEASUREMENTS OF DOSE FROM SECONDARY RADIATION OUTSIDE A TREATMENT FIELD [J].
KASE, KR ;
SVENSSON, GK ;
WOLBARST, AB ;
MARKS, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (08) :1177-1183
[9]   PHOTONEUTRONS FROM HIGH-ENERGY MEDICAL LINEAR ACCELERATORS - MEASUREMENT OF THE SPECTRUM AND DOSE USING A MINIATURE PROPORTIONAL COUNTER [J].
KLIAUGA, P ;
AMOLS, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03) :629-633
[10]   A METHOD OF CALCULATING PERIPHERAL DOSE DISTRIBUTIONS OF PHOTON BEAMS BELOW 10-MV [J].
MCPARLAND, BJ ;
FAIR, HI .
MEDICAL PHYSICS, 1992, 19 (02) :283-293