RETRACTED: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery (Retracted Article)

被引:110
作者
Mayer, J. [1 ]
Boldt, J. [1 ]
Schoellhorn, T. [1 ]
Roehm, K. D. [1 ]
Mengistu, A. M. [1 ]
Suttner, S. [1 ]
机构
[1] Klinikum Stadt Ludwigshafen, Dept Anaesthesiol & Intens Care Med, D-67063 Ludwigshafen, Germany
关键词
measurement techniques; thermodilution; monitoring; cardiopulmonary; surgery; cardiovascular;
D O I
10.1093/bja/ael341
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Thermodilution technique using a pulmonary artery catheter (PAC) is a widely used method to determine cardiac output (CO). It is increasingly criticized because of its invasiveness and its unclear risk-benefit ratio. Thus, less invasive techniques for measuring CO are highly desirable. We compared a new, semi-invasive device (Flo Trac/Vigileo (TM)) using arterial pressure waveform analysis for CO measurement in patients undergoing cardiac surgery with bolus thermodilution measurements. Methods. Forty patients undergoing coronary artery bypass grafting or valve repair were enrolled. A PAC was inserted and routine radial arterial access was used for semi-invasive determination of CO with the Vigileo. CO was measured simultaneously by bolus thermodilution and the Vigileo technique after induction of anaesthesia (T1), before cardiopulmonary bypass (CPB) (T2), after CPB (T3), after sternal closure (T4), on arrival in the intensive care unit (ICU) (T5), and 4 h (T6), 8 h (T7), and 24 h after surgery (T8). CO was indexed to the body surface area (cardiac index, CI). Results. A total of 244 pairs of CI measurements were analysed. Bias and precision (1.96 SD of the bias) were 0.46 litre min(-1) m(-2) and +/- 1.15 litre min(-1) m(-2) (r = 0.53) resulting in an overall percentage error of 46%. Subgroup analysis revealed a percentage error of 51% for data pairs obtained intraoperatively (T1-T4), 42% in ICU (T5-T8), and 56% for values obtained during low CI (T1-T8). Conclusions. In cardiac surgery patients, CO measured by a new semi-invasive arterial pressure waveform analysis device showed only moderate agreement with intermittent pulmonary artery thermodilution measurement.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 20 条
  • [1] Cardiac output measurement by pulse dye densitometry in cardiac surgery
    Baulig, W
    Bernhard, EO
    Bettex, D
    Schmidlin, D
    Schmid, ER
    [J]. ANAESTHESIA, 2005, 60 (10) : 968 - 973
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [4] COSTA MG, 2006, CONTINUOUS ARTERIAL
  • [5] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [6] Gödje O, 2002, CRIT CARE MED, V30, P52
  • [7] Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
    Harvey, S
    Harrison, DA
    Singer, M
    Ashcroft, J
    Jones, CM
    Elbourne, D
    Brampton, W
    Williams, D
    Young, D
    Rowan, K
    [J]. LANCET, 2005, 366 (9484) : 472 - 477
  • [8] Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform
    Hirschl, MM
    Binder, M
    Gwechenberger, M
    Herkner, H
    Bur, A
    Kittler, H
    Laggner, AN
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (11) : 1909 - 1914
  • [9] Simultaneous comparison of thoracic bioimpedance and arterial pulse waveform-derived cardiac output with thermodilution measurement
    Hirschl, MM
    Kittler, H
    Woisetschläger, C
    Siostrzonek, P
    Staudinger, T
    Kofler, J
    Oschatz, E
    Bur, A
    Gwechenberger, M
    Laggner, AN
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (06) : 1798 - 1802
  • [10] FREQUENCY OF TECHNICAL PROBLEMS ENCOUNTERED IN THE MEASUREMENT OF PULMONARY-ARTERY WEDGE PRESSURE
    MORRIS, AH
    CHAPMAN, RH
    GARDNER, RM
    [J]. CRITICAL CARE MEDICINE, 1984, 12 (03) : 164 - 170