Automated screening using microfluidic chip-based PCR and product detection to assess risk of BK virus-associated nephropathy in renal transplant recipients

被引:57
作者
Kaigala, Govind V.
Huskins, Ryan J.
Preiksaitis, Jutta
Pang, Xiao-Li
Pilarski, Linda M.
Backhouse, Christopher J.
机构
[1] Univ Alberta, Appl Miniaturizat Lab, Dept Elect & Comp Engn, Edmonton, AB, Canada
[2] Cross Canc Inst, Dept Oncol, Edmonton, AB, Canada
[3] Provincial Labs Publ Hlth, Edmonton, AB, Canada
关键词
CE; microchip; microfluidics; patient screening; PCR; virus detection;
D O I
10.1002/elps.200600061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The cost-effective detection of viral particles in bodily fluids could enable more effective responses to viral outbreaks, whether isolated clinical cases, or influenza epidemics. In renal transplant recipients, complications arising from high levels of BK virus can lead to graft dysfunction, graft loss, and/or reduced patient survival. We describe a microfluidic system for the sensitive analysis of BK virus (viral load) in unprocessed urine samples that are applied directly onto the chip, thus avoiding labor-intensive processing and sources of inter-assay variability. Integration of small volume genetic amplification (PCR) and electrophoretic analysis detects as few as 1-2 viral copies, distinguishes between high, medium and low levels of virus and reliably identifies viral loads requiring clinical intervention. As a first step to wider application in the clinic and in the field, the present work presents an entirely microchip-based system, validated against conventional clinical methods using clinical samples.
引用
收藏
页码:3753 / 3763
页数:11
相关论文
共 49 条
[1]  
Backhouse C, 2000, ELECTROPHORESIS, V21, P150, DOI 10.1002/(SICI)1522-2683(20000101)21:1<150::AID-ELPS150>3.0.CO
[2]  
2-5
[3]   Incidence of BK with tacrolimus versus cyclosporine and impact of preemptive immunosuppression reduction [J].
Brennan, DC ;
Agha, I ;
Bohl, DL ;
Schnitzler, MA ;
Hardinger, HL ;
Lockwood, M ;
Torrence, S ;
Schuessler, R ;
Roby, T ;
Gaudreault-Keener, M ;
Storch, GA .
AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 (03) :582-594
[4]  
Bressollette-Bodin C, 2004, INT J ANTIMICROB AG, V24, pS99
[5]   Influence of surveillance renal allograft biopsy on diagnosis and prognosis of polyomavirus-associated nephropathy [J].
Buehrig, CK ;
Lager, DJ ;
Stegall, MD ;
Kreps, MA ;
Kremers, WK ;
Gloor, JM ;
Schwab, TR ;
Velosa, JA ;
Fidler, ME ;
Larson, TS ;
Griffin, MD .
KIDNEY INTERNATIONAL, 2003, 64 (02) :665-673
[6]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[7]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[8]   The new generation of microvalves [J].
Felton, MJ .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :429A-432A
[9]   Developments toward a complete micro-total analysis system for Duchenne muscular dystrophy diagnosis [J].
Ferrance, JP ;
Wu, QR ;
Giordano, B ;
Hernandez, C ;
Kwok, Y ;
Snow, K ;
Thibodeau, S ;
Landers, JP .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :223-236
[10]   Microfluidic approaches to malaria detection [J].
Gascoyne, P ;
Satayavivad, J ;
Ruchirawat, M .
ACTA TROPICA, 2004, 89 (03) :357-369