New low-contrast vision charts: reliability and test characteristics in patients with multiple sclerosis

被引:80
作者
Balcer, LJ
Baier, ML
Pelak, VS
Fox, RJ
Shuwairi, S
Galetta, SL
Cutter, GR
Maguire, MG
机构
[1] Univ Penn, Sch Med, Dept Neurol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Ophthalmol, Philadelphia, PA 19104 USA
[3] Univ Penn, Sch Med, Dept Biostat, Philadelphia, PA 19104 USA
[4] AMC Canc Res Ctr, Dept Biostat, Denver, CO USA
[5] Univ Colorado, Hlth Sci Ctr, Dept Neurol, Denver, CO 80262 USA
关键词
vision; contrast letter acuity; multiple sclerosis; MS; reliability; outcome measures;
D O I
10.1177/135245850000600305
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The quantitative assessment of visual function in multiple sclerosis (MS) clinical trials has been limited to Snellen visual acuity. The purpose of this study was to examine the inter-rater reliability and test characteristics of a new visual outcome measure, the Low-Contrast Sloan Letter Charts, in Patients with MS and visually-asymptomatic volunteers. Contrast letter acuity scores (letter scores) were measured or each of four contrast levels (100, 5, 1.25 and 0.6%) by two independent raters. Inter-rater agreement was described with the intraclass correlation coefficient (ICC) and comparison of mean scores. Excellent inter-rater agreement (ICC=0.86-0.95) was demonstrated at each contrast level among MS Patients (n=100) and visually-asymptomotic volunteers (n=33). Average letter scores at the lowest contrast level (0.6%) were highly variable in the MS group, even among patients with visual acuities of 20/20 or better, and among those who required no assistance for ambulation. Low-Contrast Sloan Letter Chart testing is a highly reliable method of visual assessment, and Provides information on on aspect of neurologic impairment in MS which is not captured by Snellen visual acuity or ambulation status. This new method demonstrates excellent Potential as a visual function outcome measure for future MS clinical trials.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 64 条
[11]  
BECK RW, 1993, CLIN VISION SCI, V8, P207
[12]  
BECK RW, 1993, OPHTHALMOLOGY, V100, P691
[13]   REPRODUCIBILITY OF REFRACTION AND VISUAL-ACUITY MEASUREMENT UNDER A STANDARD PROTOCOL [J].
BLACKHURST, DW ;
MAGUIRE, MG .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1989, 9 (03) :163-169
[14]   A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[15]   VISUAL-ACUITY AND CONTRAST SENSITIVITY IN PATIENTS WITH CEREBRAL LESIONS [J].
BODISWOL.I .
SCIENCE, 1972, 178 (4062) :769-&
[16]   MEASUREMENT OF SPATIAL CONTRAST SENSITIVITY IN CASES OF BLURRED VISION ASSOCIATED WITH CEREBRAL LESIONS [J].
BODISWOLLNER, I ;
DIAMOND, SP .
BRAIN, 1976, 99 (DEC) :695-710
[17]  
Cleary PA, 1997, J NEURO-OPHTHALMOL, V17, P18
[18]   Development of a multiple sclerosis functional composite as a clinical trial outcome measure [J].
Cutter, GR ;
Baier, ML ;
Rudick, RA ;
Cookfair, DL ;
Fischer, JS ;
Petkau, J ;
Syndulko, K ;
Weinshenker, BG ;
Antel, JP ;
Confavreux, C ;
Ellison, GW ;
Lublin, F ;
Miller, AE ;
Rao, SM ;
Reingold, S ;
Thompson, A ;
Willoughby, E .
BRAIN, 1999, 122 :871-882
[19]   A COMPARISON OF CONFIDENCE-INTERVAL METHODS FOR THE INTRACLASS CORRELATION-COEFFICIENT [J].
DONNER, A ;
WELLS, G .
BIOMETRICS, 1986, 42 (02) :401-412
[20]   Standardizing the measurement of visual acuity for clinical research studies - Guidelines from the eye care technology forum [J].
Ferris, FL ;
Bailey, I .
OPHTHALMOLOGY, 1996, 103 (01) :181-182