Magnetic resonance imaging of short T2 components in tissue

被引:262
作者
Gatehouse, PD
Bydder, GM
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Fac Med,MRC Clin Sci Ctr, Imaging Sci Dept,Robert Steiner Magnet Resonance, London W12 0HS, England
[2] Royal Brompton Hosp, Cardiac Magnet Resonance Unit, London SW3 6LY, England
关键词
magnetic resonance imaging; short T-2 components; ultrashort echo times;
D O I
10.1053/crad.2003.1157
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The most widely used clinical magnetic resonance imaging techniques for the diagnosis of parenchymal disease employ heavily T-2-weighted sequences to detect an increase or decrease in the signal from long T-2 components in tissue. Tissues also contain short T-2 components that are not detected or only poorly detected with conventional sequences. These components are the majority species in tendons, ligaments, menisci, periosteum, cortical bone and other related tissues, and the minority in many other tissues that have predominantly long T-2 components. The development and clinical application of techniques to detect short T-2 components are just beginning. Such techniques include magic angle imaging, as well as short echo time (TE), and ultrashort TE (Ute) pulse sequences. Magic angle imaging increases the T-2 of highly ordered, collagen-rich tissues such as tendons and ligaments so signal can be detected from them with conventional pulse sequences. Ute sequences detect short T-2 components before they have decayed, both in tissues with a majority of short T-2 components and those with a minority. In the latter case steps usually need to be taken to suppress the signal from the majority of long T-2 components. Fat suppression of different types may also be helpful. Once signal from short T-2 components has been detected, different pulse sequences can be used to determine increases or decreases in T-1 and T-2 and study contrast enhancement. Using these approaches, signals have been detected from normal tissues with a majority of short T-2 components such as tendons, ligaments, menisci, periosteum, cortical bone, dentine and enamel (the latter four tissues for the first time) as well as from the other tissues in which short T-2 components are a minority. Some diseases such as chronic fibrosis, gliosis, haemorrhage and calcification may increase the signal from short T-2 components while others such as loss of tissue, loss of order in tissue and an increase in water content may decrease them. Changes of these types have been demonstrated in tendonopathy, intervertebral disc disease, ligament injury, haemachromatosis, pituitary perivascular fibrosis, gliomas, multiple sclerosis and angiomas. Use of these techniques has reduced the limit of clinical delectability of short T-2 components by about two orders of magnitude from about 10 ms to about 100 mus. As a consequence it is now possible to study tissues that have a majority of short T-2 Components with both "bright" and "dark" approaches, with the bright (high signal) approach offering options for developing tissue contrast of different types, as well as the potential for tissue characterization. In addition, tissues with a minority of short T-2 components may demonstrate changes in disease that are not apparent with conventional heavily T-2-weighted sequences. (C) 2003 The Royal College of Radiologists. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 31 条
[1]   NUCLEAR MAGNETIC RESONANCE STUDY OF COLLAGEN HYDRATION [J].
BERENDSEN, HJC .
JOURNAL OF CHEMICAL PHYSICS, 1962, 36 (12) :3297-&
[2]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[3]  
Borthakur A, 1998, P INT SOC MAGN RESON, P1804
[4]   Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging [J].
Brossmann, J ;
Frank, LR ;
Pauly, JM ;
Boutin, RD ;
Pedowitz, RA ;
Haghighi, P ;
Resnick, D .
RADIOLOGY, 1997, 203 (02) :501-507
[5]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[6]   ORIENTATION OF TENDONS IN THE MAGNETIC-FIELD AND ITS EFFECT ON T2 RELAXATION-TIMES [J].
FULLERTON, GD ;
CAMERON, IL ;
ORD, VA .
RADIOLOGY, 1985, 155 (02) :433-435
[7]  
FUNDUK N, 1984, MAGN RESON MED, V1, P66, DOI 10.1002/mrm.1910010108
[8]   MR imaging of articular cartilage of the knee: New methods using ultrashort TEs [J].
Gold, GE ;
Thedens, D ;
Pauly, JM ;
Fechner, KP ;
Bergman, G ;
Beaulieu, CF ;
Macovski, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1223-1226
[9]   MR SPECTROSCOPIC IMAGING OF COLLAGEN - TENDONS AND KNEE MENISCI [J].
GOLD, GE ;
PAULY, JM ;
MACOVSKI, A ;
HERFKENS, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) :647-654
[10]   Dipolar contrast for dense tissues imaging [J].
Grenier, D ;
Pascui, O ;
Briguet, A .
JOURNAL OF MAGNETIC RESONANCE, 2000, 147 (02) :353-356