The design of single particle laser mass spectrometers

被引:165
作者
Murphy, Daniel M. [1 ]
机构
[1] NOAA, Earth Syst Res Lab, Boulder, CO 80303 USA
关键词
aerosol; inlet; mass spectrometer; laser;
D O I
10.1002/mas.20113
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This review explores some of the design choices made with single particle mass spectrometers. Different instruments have used various configurations of inlets, particle sizing techniques, ionization lasers, mass spectrometers, and other components. Systematic bias against non-spherical particles probably exceeds a factor of 2 for all instruments. An ionization laser tradeoff is the relatively poor beam quality and reliability of an excimer laser versus the longer wavelengths and slower response time of an Nd-YAG laser Single particle instruments can make special demands on the speed and dynamic range of the mass spectrometers. This review explains some of the choices made for instruments that were developed for different types of measurements in the atmosphere. Some practical design notes are also given from the author's experience with each section of the instrument. Published 2006 Wiley Periodicals, Inc.
引用
收藏
页码:150 / 165
页数:16
相关论文
共 96 条
[51]   AEROSOL MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY [J].
MURRAY, KK ;
RUSSELL, DH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (01) :1-9
[52]   On-line analysis of aqueous aerosols by laser desorption ionization [J].
Neubauer, KR ;
Johnston, MV ;
Wexler, AS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 163 (1-2) :29-37
[53]   Humidity effects on the mass spectra of single aerosol particles [J].
Neubauer, KR ;
Johnston, MV ;
Wexler, AS .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (14-15) :2521-2529
[54]  
Noble CA, 2000, MASS SPECTROM REV, V19, P248, DOI 10.1002/1098-2787(200007)19:4<248::AID-MAS3>3.3.CO
[55]  
2-9
[56]  
OBA K, 1981, IEEE T NUCL SCI, V28, P683, DOI 10.1109/TNS.1981.4331263
[57]   RESOLUTION IN THE LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
OPSAL, RB ;
OWENS, KG ;
REILLY, JP .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1884-1889
[58]   A PULSED MICROCHANNEL-PLATE-BASED NONNEUTRAL PLASMA IMAGING-SYSTEM [J].
PEURRUNG, AJ ;
FAJANS, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01) :52-55
[59]   Performance of a single ultrafine particle mass spectrometer [J].
Phares, DJ ;
Rhoads, KP ;
Wexler, AS .
AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (05) :583-592
[60]   Application of the ART-2a algorithm to laser ablation aerosol mass spectrometry of particle standards [J].
Phares, DJ ;
Rhoads, KP ;
Wexler, AS ;
Kane, DB ;
Johnston, MV .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2338-2344