New perspectives on catheter-based ablation of ventricular tachycardia complicating Chagas' disease: Experimental evidence of the efficacy of near infrared lasers for catheter ablation of Chagas' VT

被引:28
作者
d'Avila, A
Splinter, R
Svenson, RH
Scanavacca, M
Pruitt, E
Kasell, J
Sosa, E
机构
[1] Univ Sao Paulo, Sch Med, Heart Inst InCor, Unit Cardiac Arrhythmia, BR-05508 Sao Paulo, Brazil
[2] Carolinas Med Ctr, Laser & Appl Technol Lab, Charlotte, NC 28203 USA
[3] Univ N Carolina, Charlotte, NC 28223 USA
[4] Sanger Clin PA, Charlotte, NC USA
[5] Carolinas Heart Inst, Charlotte, NC USA
[6] Lightwave Ablat Syst Inc, Mooresville, NC USA
关键词
Chagas' disease; ventricular tachycardia; catheter ablation; light energy;
D O I
10.1023/A:1020811915133
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chronic Chagas' myocarditis can alter the myocardial substrate in a way that facilitates the emergence of fatal VT in a way similar to the long-term consequences of myocardial infarction. Post-myocardial infarction and Chagas' VT share many similarities: they are both macroreentrant circuits, entrainable, involving any wall segment from the endocardium to the epicardium. However, as compared to patients with post-MI VT, Chagasic patients tend to be younger and have a higher left ventricular ejection fraction. It is assumed, therefore, that their prognosis is closely related to VT treatment rather than the progression of the myocardial damage caused by the disease itself. Although sudden death is a rare event in patients in NYHA functional class I and II treated with amiodarone, VT recurrence rate is 30% a year. Drug therapy is ineffective for patients with advanced heart failure (100% recurrence rate/40% mortality in 1 year). Open-chest surgery is effective but requires very specialized centers and great expertise making its widespread use unrealistic. The results of combining RF endo/epicardial catheter ablation are still disappointing. Thus, research protocols on the search for new ablation technologies may greatly impact overall mortality in this subset of patients. This review will focus on the limitations of the current catheter-based ablation technology and suggest that an alternative approach is urgently needed. Experimental evidence of the efficacy of near infrared Lasers for catheter ablation will be reported along with investigations of the optical properties of the chagasic myocardium in the near infrared region to indicate that it might be not only feasible but also an appropriate choice to treat these patients.
引用
收藏
页码:23 / 38
页数:16
相关论文
共 52 条
  • [21] RADIOFREQUENCY CATHETER ABLATION OF SUSTAINED VENTRICULAR-TACHYCARDIA IN IDIOPATHIC DILATED CARDIOMYOPATHY
    KOTTKAMP, H
    HINDRICKS, G
    CHEN, X
    BRUNN, J
    WILLEMS, S
    HAVERKAMP, W
    BLOCK, M
    BREITHARDT, G
    BORGGREFE, M
    [J]. CIRCULATION, 1995, 92 (05) : 1159 - 1168
  • [22] PERICARDIOCENTESIS
    KRIKORIAN, JG
    HANCOCK, EW
    [J]. AMERICAN JOURNAL OF MEDICINE, 1978, 65 (05) : 808 - 814
  • [23] CONCEALED ENTRAINMENT AS A GUIDE FOR CATHETER ABLATION OF VENTRICULAR-TACHYCARDIA IN PATIENTS WITH PRIOR MYOCARDIAL-INFARCTION
    MORADY, F
    KADISH, A
    ROSENHECK, S
    CALKINS, H
    KOU, WH
    DEBUITLEIR, M
    SOUSA, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (03) : 678 - 689
  • [24] ULTRASTRUCTURAL CHARACTERISTICS OF DIFFERENT STAGES OF HUMAN CHAGASIC MYOCARDITIS
    PALACIOSPRU, E
    CARRASCO, H
    SCORZA, C
    ESPINOZA, R
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1989, 41 (01) : 29 - 40
  • [25] ELECTROPHYSIOLOGIC FINDINGS IN LONG-TERM ASYMPTOMATIC CHAGASIC INDIVIDUALS
    PIMENTA, J
    MIRANDA, M
    PEREIRA, CB
    [J]. AMERICAN HEART JOURNAL, 1983, 106 (02) : 374 - 380
  • [26] Prata A., 1975, AM TRYPANOSOMIASIS R, V318, P191
  • [27] CHAGASIC MYOCARDIOPATHY
    ROSENBAUM, MB
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1964, 7 (03) : 199 - 225
  • [28] Scanavacca M, 1995, Sao Paulo Med J, V113, P841
  • [29] Scanavacca M I, 1990, Arq Bras Cardiol, V54, P367
  • [30] SHUKES S, 1993, P IEEE EMBS, V15, P1602