Endoscopic ultrasound guided fine-needle aspiration cytology of pancreatic carcinoma - A 3-year experience and review of the literature

被引:82
作者
Ylagan, LR
Edmundowicz, S
Kasal, K
Walsh, D
Lu, DW
机构
[1] Washington Univ, Sch Med, Lauren V Ackerman Lab Surg Pathol, Div Cytopathol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Med, Div Gastroenterol, St Louis, MO 63110 USA
关键词
endoscopic ultrasound-guided fine-needle aspiration (EUS-FNAB); cytology; pancreas; adenocarcinoma;
D O I
10.1002/cncr.10759
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BACKGROUND. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) of small pancreatic lesions that are undetectable by computed tomography has gained wide acceptance for the procurement of cells for diagnostic purposes. However, this technique is not without difficulty. The authors examined the sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) of this technique in the evaluation of patients with pancreatic biliary duct strictures/masses. The authors were interested in reviewing their cases of pancreatic adenocarcinoma of ductal type and finding the sources of their false-negative cases. METHODS. A computer search was performed between January 1998 and July 2001. For the last 3 years, a total of 80 cases of suspected ductal adenocarcinoma of the pancreas was identified. Thirty-four patients (42%) underwent a subsequent Whipple procedure or biopsy. Cytologic and histologic correlation was performed in these cases. The rest of the 23 patients (29%) considered to be positive and the 23 patients (29%) considered to be negative underwent no subsequent biopsy and were followed clinically. Cases termed "suspicious" on cytology were considered positive and those termed "atypical cytology" were considered negative in the authors' final calculation. The causes of the false-negative diagnoses were evaluated carefully. RESULTS. of the 34 cases followed with subsequent tissue biopsy or surgery; 12 were confirmed to be positive, 12 were confirmed to be negative, and 10 were considered to be false-negative. Previously identified cytomorphologic features of malignancy were used to review all cases. These features were: loss of the honeycomb pattern (100%), anisonucleosis (100%), nuclear contour irregularity (100%), a high nuclear/cytoplasmic ratio (100%), paranuclear chromatin clearing (77%), and the presence of prominent nucleoli in the absence of inflammatory cells (77%). The causes of the 10 false-negative cases were technical difficulty of procuring material in 6 cases, the nature of the lesion in 2 cases, and the scarcity of lesional tissue in 2 cases. CONCLUSIONS. Using strict cytoarchitectural and cytomorphologic criteria of malignancy for ductal pancreatic lesions previously described in the literature, the sensitivity of this technique at the study institution was 78% with a specificity of 100%. The PPV and NPV of this technique were 100% and 78%, respectively. The most common causes of the false-negative results in descending order were the technical aspect of the procedure, the size and nature of the lesion, and the scarcity of lesional tissue. (C) 2002 American Cancer Society.
引用
收藏
页码:362 / 369
页数:8
相关论文
共 42 条
[1]   Diagnostic value of brush cytology in the diagnosis of duodenal, biliary, and ampullary neoplasms [J].
Bardales, RH ;
Stanley, MW ;
Simpson, DD ;
Baker, SJ ;
Steele, CT ;
Schaefer, RF ;
Powers, CN .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 109 (05) :540-548
[2]  
Bentz JS, 1998, DIAGN CYTOPATHOL, V18, P98, DOI 10.1002/(SICI)1097-0339(199802)18:2<98::AID-DC4>3.0.CO
[3]  
2-P
[4]   Endoscopic ultrasound guided fine needle aspiration of malignant pancreatic lesions [J].
Bhutani, MS ;
Hawes, RH ;
Baron, PL ;
Sanders-Cliette, A ;
van Velse, A ;
Osborne, JF ;
Hoffman, BJ .
ENDOSCOPY, 1997, 29 (09) :854-858
[5]   Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope [J].
Binmoeller, KF ;
Thul, R ;
Rathod, V ;
Henke, P ;
Brand, B ;
Jabusch, HC ;
Soehendra, N .
GASTROINTESTINAL ENDOSCOPY, 1998, 47 (02) :121-127
[6]  
Chang K J, 1995, Gastrointest Endosc Clin N Am, V5, P723
[7]   The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma [J].
Chang, KJ ;
Nguyen, P ;
Erickson, RA ;
Durbin, TE ;
Katz, KD .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (05) :387-393
[8]   PANCREATIC ADENOCARCINOMA - REGRESSION-ANALYSIS TO IDENTIFY IMPROVED CYTOLOGIC CRITERIA [J].
COHEN, MB ;
EGERTER, DP ;
HOLLY, EA ;
AHN, DK ;
MILLER, TR .
DIAGNOSTIC CYTOPATHOLOGY, 1991, 7 (04) :341-345
[9]  
COHEN MB, 1995, MODERN PATHOL, V8, P498
[10]  
dePeraltaVenturina MN, 1996, DIAGN CYTOPATHOL, V14, P334, DOI 10.1002/(SICI)1097-0339(199605)14:4<334::AID-DC12>3.0.CO