Enzymatic degradation behavior and mechanism of poly(lactide-co-glycolide) foams by trypsin

被引:147
作者
Cai, Q [1 ]
Shi, GX [1 ]
Bei, JZ [1 ]
Wang, SG [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, Ctr Mol Sci, Beijing 100080, Peoples R China
关键词
poly(lactide-co-glycolidc); enzymatic degradation; hydrolytic degradation; trypsin;
D O I
10.1016/S0142-9612(02)00377-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to investigate the enzymatic degradation behaviors of porous poly(lactide-co-glycolide) (PLGA) foams in the presence of trypsin, in comparison with their hydrolytic degradation. To inspect the effect of trypsin oil tile degradation of PLGA, both the hydrolytic and enzymatic degradation of non-porous PLGA samples were also performed. The changes of molecular weight and molecular weight distribution (polydispersity) during the degradation were determined by gel permeation chromatograph. And the changes of weight, thickness and morphology with the degradation were also measured. The degradation of PLGA displayed as two stages. In the first stage, the molecular weight of PLGA decreased continuously with degradation time, whereas little weight loss occurred. But in the second stage, the molecular weight of PLGA had decreased to a low value and was almost unchanged with time, while the sample experienced significant weight loss. And it was found that the presence of trypsin could significantly accelerate the weight loss rates of all the PLGA samples, but it Caused little difference in the decrease of molecular weight and the change of PLGA composition between the enzymatic and hydrolytic degradation. Therefore, the enzymatic degradation of PLGA was still primarily a hydrolysis process. A mechanism of enzymatic degradation was proposed that the trypsin could enhance the weight loss of PLGA by acting as surfactant to push the dispersion of degradation products into water even though they could not dissolve in water. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:629 / 638
页数:10
相关论文
共 44 条
[1]   MECHANISMS OF POLYMER DEGRADATION IN IMPLANTABLE DEVICES .2. POLY(DL-LACTIC ACID) [J].
ALI, SAM ;
DOHERTY, PJ ;
WILLIAMS, DF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (11) :1409-1418
[2]  
Andriano KP, 1999, J BIOMED MATER RES, V48, P602, DOI 10.1002/(SICI)1097-4636(1999)48:5<602::AID-JBM3>3.0.CO
[3]  
2-6
[4]  
[Anonymous], CHIN J FUNCTIONAL PO
[5]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[6]   The effects of porosity on in vitro degradation of polylactic acid polyglycolic acid implants used in repair of articular cartilage [J].
Athanasiou, KA ;
Schmitz, JP ;
Agrawal, CM .
TISSUE ENGINEERING, 1998, 4 (01) :53-63
[7]   Host response to tissue engineered devices [J].
Babensee, JE ;
Anderson, JM ;
McIntire, LV ;
Mikos, AG .
ADVANCED DRUG DELIVERY REVIEWS, 1998, 33 (1-2) :111-139
[8]   CONTROLLED DELIVERY SYSTEMS FOR PROTEINS BASED ON POLY(LACTIC GLYCOLIC ACID) MICROSPHERES [J].
COHEN, S ;
YOSHIOKA, T ;
LUCARELLI, M ;
HWANG, LH ;
LANGER, R .
PHARMACEUTICAL RESEARCH, 1991, 8 (06) :713-720
[9]   The control of protein release from poly(DL-lactide co-glycolide) microparticles by variation of the external aqueous phase surfactant in the water-in oil-in water method [J].
Coombes, AGA ;
Yeh, MK ;
Lavelle, EC ;
Davis, SS .
JOURNAL OF CONTROLLED RELEASE, 1998, 52 (03) :311-320
[10]   BIODEGRADABLE POLYMER SCAFFOLDS FOR TISSUE ENGINEERING [J].
FREED, LE ;
VUNJAKNOVAKOVIC, G ;
BIRON, RJ ;
EAGLES, DB ;
LESNOY, DC ;
BARLOW, SK ;
LANGER, R .
BIO-TECHNOLOGY, 1994, 12 (07) :689-693