Potentiometric and UV-vis characterisation of N-substituted polyanilines

被引:65
作者
Lindfors, T [1 ]
Ivaska, A [1 ]
机构
[1] Abo Akad Univ, Analyt Chem Lab, Proc Chem Grp, FIN-20500 Turkul Abo, Finland
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 535卷 / 1-2期
基金
芬兰科学院;
关键词
N-substituted polyanilines; electropolymerisation; conducting polymer; pH sensitivity; potentiometry; UV-vis spectroscopy; DBSA;
D O I
10.1016/S0022-0728(02)01172-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(N-methylaniline) (PNMeANI), poly(N-ethylaniline) (PNEtANI), poly(N-propylaniline) (PNPrANI) and poly(N-butylani-line) (PNBuANI) films were polymerised on glassy carbon and tin oxide (TO) substrates in 1.0 M HClO4. The pH sensitivity of the polymer films was investigated with potentiometry and UV-vis measurements in aqueous buffer solutions with pH 2-9. The results of these measurements were compared with polyaniline (PANI) prepared in 1.0 M HCl In this study, the potential and the UV-vis spectrum of the different polymer films deposited on TO were measured simultaneously. These optopotentiometric measurements give information about the surface and bulk processes in the N-substituted polyaniline films when they are in contact with the buffer solutions of different pH. It was shown that the N-substituted polyaniline films were not pH sensitive. The suppressed potentiometric pH sensitivity of the N-substituted polyanilines, which were observed when changing pH, are caused by reduction of the polymer films from their emeraldine to leucoemeraldine oxidation state. Polymerisation of PNMeANI in 0.1 M dodecylbenzenesulphonic acid (DBSA) solution is also reported in this paper. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 38 条
[1]   ALTERATION OF THE ION-EXCHANGE MECHANISM OF AN ELECTROACTIVE POLYMER BY MANIPULATION OF THE ACTIVE-SITE - PROBE BEAM DEFLECTION AND QUARTZ CRYSTAL MICROBALANCE STUDY OF POLY(ANILINE) AND POLY(N-METHYLANILINE) [J].
BARBERO, C ;
MIRAS, MC ;
HAAS, O ;
KOTZ, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 310 (1-2) :437-443
[2]   MECHANISM OF IONIC AND REDOX SENSITIVITY OF P-TYPE CONDUCTING POLYMERS .2. EXPERIMENTAL-STUDY OF POLYPYRROLE [J].
BOBACKA, J ;
GAO, ZQ ;
IVASKA, A ;
LEWENSTAM, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :33-41
[3]   SINGLE PIECE ALL-SOLID-STATE ION-SELECTIVE ELECTRODE [J].
BOBACKA, J ;
LINDFORS, T ;
MCCARRICK, M ;
IVASKA, A ;
LEWENSTAM, A .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3819-3823
[4]   ALL-SOLID-STATE SODIUM-SELECTIVE ELECTRODE BASED ON A CALIXARENE IONOPHORE IN A POLY(VINYL CHLORIDE) MEMBRANE WITH A POLYPYRROLE SOLID CONTACT [J].
CADOGAN, A ;
GAO, ZQ ;
LEWENSTAM, A ;
IVASKA, A ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2496-2501
[5]   COUNTERION INDUCED PROCESSIBILITY OF CONDUCTING POLYANILINE AND OF CONDUCTING POLYBLENDS OF POLYANILINE IN BULK POLYMERS [J].
CAO, Y ;
SMITH, P ;
HEEGER, AJ .
SYNTHETIC METALS, 1992, 48 (01) :91-97
[6]   SYNTHESIS, CHARACTERIZATION, AND PROPERTIES OF POLY(N-ALKYLANILINES) [J].
CHEVALIER, JW ;
BERGERON, JY ;
DAO, LH .
MACROMOLECULES, 1992, 25 (13) :3325-3331
[7]   COMPARISON OF CHEMICALLY AND ELECTROCHEMICALLY PREPARED POLYANILINE FILMS .2. OPTICAL-PROPERTIES [J].
CHINN, D ;
DUBOW, J ;
LI, J ;
JANATA, J ;
JOSOWICZ, M .
CHEMISTRY OF MATERIALS, 1995, 7 (08) :1510-1518
[8]   CHEMICAL AND ELECTROCHEMICAL SYNTHESIS AND CHARACTERIZATION OF POLYDIPHENYLAMINE AND POLY-N-METHYLANILINE [J].
COMISSO, N ;
DAOLIO, S ;
MENGOLI, G ;
SALMASO, R ;
ZECCHIN, S ;
ZOTTI, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 255 (1-2) :97-110
[9]   Potentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes [J].
Cui, G ;
Lee, JS ;
Kim, SJ ;
Nam, H ;
Cha, GS ;
Kim, HD .
ANALYST, 1998, 123 (09) :1855-1859
[10]  
de Marcos S, 2000, QUIM ANAL, V19, P99