An in vitro comparison of canal preparation using two automated rotary nickel-titanium instrumentation techniques

被引:19
作者
Jardine, SJ [1 ]
Gulabivala, K [1 ]
机构
[1] UCL, Eastman Dent Inst Oral Hlth Care Sci, Dept Conservat Dent, London WC1X 8LD, England
关键词
canal preparation; nickel-titanium; rotary;
D O I
10.1046/j.1365-2591.2000.00327.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study was to compare the efficacy of root canal preparation using two automated rotary nickel-titanium instrumentation techniques with a double flared balanced forces hand preparation technique, using stainless steel files in extracted human teeth. Methodology Sixty root canals in extracted human teeth were matched for curvature, length and diameter and divided evenly between three groups (group 1 = double flare using Flexofiles(R), group 2 = rotary nickel-titanium using McXIM(R) instruments and group 3 = rotary nickel-titanium using Profile(R) .04 Taper(TM) Series 29 instruments). The instruments were used according to the manufacturer's instructions in a torque controlled motor and handpiece (groups 2 and 3) and according to a predetermined procedure in group 1. A standardized radiographic technique using mercury as a contrast medium was used to evaluate the canal shape before and after preparation in the plane of maximum curvature. The pre- and postoperative radiographic images were compared against each other and with a predicted 'ideal preparation' calculated from a projection of the final instrument dimensions. The outcome measures were changes in canal dimensions as quantified by measuring the changes in the position of the inner and outer wall at 1 mm intervals. Alteration in canal curvature could be inferred by comparison with the ideal preparation. Results The degree of canal curvature did not influence the effectiveness of any of the techniques. The results showed no statistically significant differences in the outcome measures between the groups (two-way anova). There were no significant differences in canal wall position changes at any level except the apical three, where significantly less change occurred in all groups (P = 1%). Instruments fractured in three canals, with acute curves in groups 2 and 3. Conclusions Canal curvatures were equally and well maintained following preparation in all the groups, as long as the instrument did not fracture.
引用
收藏
页码:381 / 391
页数:11
相关论文
共 47 条
[21]  
HANKINS P, 1991, J ENDODONT, V17, P193
[22]  
HEUER MA, 1983, TECHNIQUES CLIN ENDO, P259
[23]   THE ENDODONTIC FILE IS A DISPOSABLE INSTRUMENT [J].
KAZEMI, RB ;
STENMAN, E ;
SPANGBERG, LSW .
JOURNAL OF ENDODONTICS, 1995, 21 (09) :451-455
[24]  
KEREKES K, 1977, Journal of Endodontics, V3, P114, DOI 10.1016/S0099-2399(77)80206-9
[25]  
KERSH M, 1993, J ENDODONT, V19, P193
[26]   A COMPARISON OF 4 INSTRUMENTATION TECHNIQUES ON APICAL CANAL TRANSPORTATION [J].
LUITEN, DJ ;
MORGAN, LA ;
BAUMGARTNER, JC ;
MARSHALL, JG .
JOURNAL OF ENDODONTICS, 1995, 21 (01) :26-32
[27]   AN EVALUATION OF THE CROWN-DOWN PRESSURELESS TECHNIQUE [J].
MORGAN, LF ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1984, 10 (10) :491-498
[28]   A STUDY OF THE CUTTING EFFICIENCY OF 7 BRANDS OF ENDODONTIC FILES IN LINEAR MOTION [J].
NEWMAN, JG ;
BRANTLEY, WA ;
GERSTEIN, H .
JOURNAL OF ENDODONTICS, 1983, 9 (08) :316-322
[29]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[30]   THE BALANCED FORCE CONCEPT FOR INSTRUMENTATION OF CURVED CANALS [J].
ROANE, JB ;
SABALA, CL ;
DUNCANSON, MG .
JOURNAL OF ENDODONTICS, 1985, 11 (05) :203-211