Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study

被引:21
作者
Hauschild, Oliver [1 ]
Konstantinidis, L. [1 ]
Strohm, P. C. [1 ]
Niemeyer, P. [1 ]
Suedkamp, N. P. [1 ]
Helwig, P. [1 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Orthoped Surg & Traumatol, D-79106 Freiburg, Germany
关键词
Computer navigation; Total knee arthroplasty; OrthoPilot system; INTRAOBSERVER ERRORS; REGISTRATION PROCESS; FREE NAVIGATION; LIMB ALIGNMENT; ARTHROPLASTY; ACCURACY; TRANSEPICONDYLAR; REPLACEMENT; LANDMARKS; AXIS;
D O I
10.1007/s00167-009-0825-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Despite the increase in clinical use of navigation systems in total knee arthroplasty, few studies have focused on the reproducibility of these systems. The aim of the present study was to assess the influence of knee position and observer experience on intra- and inter-observer agreement in limb alignment assessment with the OrthoPilot system. Limb alignment in the coronal plane and extension range of the knee were assessed in four embalmed cadaveric specimens by five independent observers and measurements were repeated four times to determine intra- and inter-observer agreement, expressed as intraclass correlation coefficients (ICCs). Additionally, navigation results were compared against figures from conventional measurement of leg alignment (ground truth). Intra- and inter-observer agreements were excellent for assessing the extension range (ICC, 0.97 and 0.95) and the coronal femuro-tibial axis in knee extension (ICC, 0.92 and 0.88) but were generally worse in knee flexion (ICC, 0.62 and 0.55). There was an increased tendency of intraobserver errors in observers with less clinical experience. Mean correlation with conventional measurements was fair (Spearman's rho 0.61). The OrthoPilot system showed excellent reproducibility for assessment of extension range and coronal limb alignment. However, assessments of coronal limb alignment in flexion were prone to error and caution should be taken when relying on these measurements.
引用
收藏
页码:1143 / 1151
页数:9
相关论文
共 32 条
[1]
ABBOTT LC, 1945, J BONE JOINT SURG, V27, P277
[2]
Bäthis H, 2006, ORTHOPADE, V35, P1056, DOI 10.1007/s00132-006-1001-3
[3]
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[4]
CT-based and CT-free navigation in total knee arthroplasty.: Results of a prospective study [J].
Bäthis, H ;
Perlick, L ;
Lüring, C ;
Kalteis, T ;
Grifka, J .
UNFALLCHIRURG, 2003, 106 (11) :935-940
[5]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[6]
Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[7]
Experiences with computer navigated total knee arthroplasty [J].
Bejek, Zoltan ;
Solyom, Laszlo ;
Szendroi, Miklos .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) :617-622
[8]
Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[9]
CAILLOUETTE JT, 1990, CLIN ORTHOP RELAT R, P198
[10]
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments