Accuracy of the conductance catheter for measurement of ventricular volumes seen clinically: Effects of electric field homogeneity and parallel conductance

被引:29
作者
Wu, CC
Skalak, TC
Schwenk, TR
Mahler, CM
Anne, A
Finnerty, PW
Haber, HL
Weikle, RM
Feldman, MD
机构
[1] UNIV VIRGINIA,DEPT BIOMED ENGN,CHARLOTTESVILLE,VA 22908
[2] UNIV VIRGINIA,DEPT ELECT ENGN,CHARLOTTESVILLE,VA 22908
关键词
conductance catheter; field homogeneity; modeling; parallel conductance;
D O I
10.1109/10.563296
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conductance-volume method is an important clinical tool which allows the assessment of left ventricular function in vivo, However, the accuracy of this method is limited bg the homogeneity of electric field the conductance catheter produces and the parallel conductance of surrounding structures, This paper examines these sources of error in, volumes seen clinically, The characteristics of electric field within a chamber were examined using computer simulation, Nonconductive and conductive models were constructed and experimental measurements obtained using both single-field (SF) and dual-field (DF) excitation. Results from computer simulations and in vitro measurements were compared to validate the proposed theoretical model of conductance-volume method, The effects of field homogeneity and significance of parallel conductance in volume measurement a-ere then determined, The results of this study show that DF provide a more accurate measure of intraventricular volume than SF, especially at larger volumes, However, both significantly underestimate true volume at larger volumes, In addition, the parallel conductance due to the chamber wall is significant at small volumes, but diminishes at larger volumes. Furthermore, the effect of parallel conductance beyond the chamber wall may be negligible. This study demonstrates the limitations in applying current conductance technology to patients with dilated hearts.
引用
收藏
页码:266 / 277
页数:12
相关论文
共 18 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [2] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [3] Acute cardiovascular effects of OPC-18790 in patients with congestive heart failure - Time- and dose-dependence analysis based on pressure-volume relations
    Feldman, MD
    Pak, PH
    Wu, CC
    Haber, HL
    Heesch, CM
    Bergin, JD
    Powers, ER
    Cowart, TD
    Johnson, W
    Feldman, AM
    Kass, DA
    [J]. CIRCULATION, 1996, 93 (03) : 474 - 483
  • [4] INTRACORONARY ANGIOTENSIN-CONVERTING ENZYME-INHIBITION IMPROVES DIASTOLIC FUNCTION IN PATIENTS WITH HYPERTENSIVE LEFT-VENTRICULAR HYPERTROPHY
    HABER, HL
    POWERS, ER
    GIMPLE, LW
    WU, CC
    SUBBIAH, K
    JOHNSON, WH
    FELDMAN, MD
    [J]. CIRCULATION, 1994, 89 (06) : 2616 - 2625
  • [5] WHY DO PATIENTS WITH CONGESTIVE-HEART-FAILURE TOLERATE THE INITIATION OF BETA-BLOCKER THERAPY
    HABER, HL
    SIMEK, CL
    GIMPLE, LW
    BERGIN, JD
    SUBBIAH, K
    JAYAWEERA, AR
    POWERS, ER
    FELDMAN, MD
    [J]. CIRCULATION, 1993, 88 (04) : 1610 - 1619
  • [6] VOLUME PROFILES OBTAINED BY A CONDUCTIMETRIC METHOD
    HERRERA, MC
    VALENTINUZZI, ME
    OLIVERA, JM
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (04): : 267 - 273
  • [7] *INT TEL TEL CO IN, 1985, REF DAT RAD ENG, P30
  • [8] USE OF A CONDUCTANCE (VOLUME) CATHETER AND TRANSIENT INFERIOR VENA-CAVAL OCCLUSION FOR RAPID-DETERMINATION OF PRESSURE-VOLUME RELATIONSHIPS IN MAN
    KASS, DA
    MIDEI, M
    GRAVES, W
    BRINKER, JA
    MAUGHAN, WL
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 15 (03): : 192 - 202
  • [9] ANALYSIS OF CONDUCTANCE VOLUMETRIC MEASUREMENT ERROR SOURCES
    KUN, S
    PEURA, RA
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (01) : 94 - 100
  • [10] CONDUCTANCE VOLUMETRIC MODEL OF AN ECCENTRICALLY POSITIONED CATHETER WITHIN A 3-COMPARTMENT ELLIPSOIDAL VENTRICLE
    KUN, S
    PEURA, RA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (06) : 589 - 593