The role of tactile feedback in laparoscopic surgery

被引:64
作者
Ottermo, Maria V.
Ovstedal, Marit
Lango, Thomas
Stavdahl, Oyvind
Yavuz, Yunus
Johansen, Tor A.
Marvik, Ronald
机构
[1] NTNU, Dept Engn Cybernet, N-7491 Trondheim, Norway
[2] SINTEF Hlth Res, Dept Med Technol, Trondheim, Norway
[3] St Olavs Hosp, Natl Ctr Adv Laparoscop Surg, Trondheim, Norway
关键词
tactile feedback; palpation; laparoscopic surgery; tactile sensor array;
D O I
10.1097/01.sle.0000213734.87956.24
中图分类号
R61 [外科手术学];
学科分类号
摘要
Two experiments aiming at comparing palpation with gloved fingers, conventional laparoscopic instruments, and a laparoscopic instrument with a sensor array attached to its end effector are described. The sensor array provides the surgeon with visually presented tactile information. Fifteen subjects were asked to discriminate hardness and size of objects (rubber balls hidden in pig's intestine) with the 3 palpation methods. The experiments showed that the gloved fingers are better at differentiating hardness and size compared with conventional laparoscopic instruments and the instrument with sensor. There was no significant difference between conventional instruments and the instrument with sensor, although the results showed a higher average score with the instrument with sensor. This indicates that visual presentation may not be an ideal way of presenting tactile information. It also indicates that the presence of the array does not make the task more difficult.
引用
收藏
页码:390 / 400
页数:11
相关论文
共 16 条
[1]  
[Anonymous], TOUCH VIRTUAL ENV
[2]   Tactile feedback is present during minimally invasive surgery [J].
Bholat, OS ;
Haluck, RS ;
Murray, WB ;
Gorman, PJ ;
Krummel, TM .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 189 (04) :349-355
[3]  
Bicchi A, 1996, IEEE INT CONF ROBOT, P884
[4]  
Box G., 2005, Statistics for Experimenters, VSecond
[5]   Sensitivity of laparoscopic dissectors - What can you feel? [J].
den Boer, KT ;
Herder, JL ;
Sjoerdsma, W ;
Meijer, DW ;
Gouma, DJ ;
Stassen, HG .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (09) :869-873
[6]   The EndoHand: Comparison with standard laparoscopic instrumentation [J].
Jackman, SV ;
Jarzemski, PA ;
Listopadzki, SM ;
Lee, BR ;
Stoianovici, D ;
Demaree, R ;
Jarrett, TW ;
Kavoussi, LR .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 1999, 9 (03) :253-258
[7]  
LEHMANN EL, 1975, NONPARAMETRICS STATI, P123
[8]   Force-feedback grasper helps restore sense of touch in minimally invasive surgery [J].
MacFarlane, M ;
Rosen, J ;
Hannaford, B ;
Pellegrini, C ;
Sinanan, M .
JOURNAL OF GASTROINTESTINAL SURGERY, 1999, 3 (03) :278-285
[9]  
OTTERMO MV, 2004, P 2004 IEEE RSJ INT, P3960
[10]   Design and modeling of an endoscopic piezoelectric tactile sensor [J].
Sedaghati, R ;
Dargahi, J ;
Singh, H .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2005, 42 (21-22) :5872-5886