Reproducibility of human kidney perfusion and volume determinations with electron beam computed tomography

被引:51
作者
Lerman, LO
Flickinger, AL
Sheedy, PF
Turner, ST
机构
[1] MAYO CLIN & MAYO FDN,DIV NEPHROL,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DIV HYPERTENS,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT RADIOL,ROCHESTER,MN 55905
关键词
renal circulation; renal volume; x-ray CT;
D O I
10.1097/00004424-199604000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Alterations in whole kidney, cortical, and medullary perfusion and volume play a pivotal role in various physiologic and pathophysiologic processes. Electron-beam computed tomography (EBCT) provides accurate measurements of these traits in animals, but their reproduciblity in humans has not been established. METHODS. Perfusion, volume, and flow measurements were obtained by EBCT in eight healthy human volunteers under controlled conditions on two consecutive days. RESULTS. Mean values for whole kidney, cortical, and medullary perfusion and volume obtained with EBCT were similar in scan 1 and scan 2 (P > 0.1), and correlated highly. Coefficients of variation for the repeated measurements usually were less than 14% Values obtained for renal regional perfusion and volume agreed with previously reported values. CONCLUSIONS. Electron-beam computed tomography estimates of single whole kidney, cortical, and medullary perfusions and volumes are highly reproducible in normal humans, and may be useful to advance understanding of renal involvement in human disease.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 52 条
[1]   INTRARENAL DISTRIBUTION OF BLOOD-FLOW - ARE RELIABLE METHODS AVAILABLE FOR MEASUREMENTS IN MAN [J].
AUKLAND, K .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 (06) :481-486
[2]   METHODS FOR MEASURING RENAL BLOOD-FLOW - TOTAL FLOW AND REGIONAL DISTRIBUTION [J].
AUKLAND, K .
ANNUAL REVIEW OF PHYSIOLOGY, 1980, 42 :543-555
[3]   3-DIMENSIONAL CANINE RENOVASCULAR STRUCTURE AND CIRCULATION VISUALIZED INSITU WITH THE DYNAMIC SPATIAL RECONSTRUCTOR [J].
BENTLEY, MD ;
HOFFMAN, EA ;
FIKSENOLSEN, MJ ;
KNOX, FG ;
RITMAN, EL ;
ROMERO, JC .
AMERICAN JOURNAL OF ANATOMY, 1988, 181 (01) :77-88
[4]   MEASUREMENT OF RENAL PERFUSION AND BLOOD-FLOW WITH FAST COMPUTED-TOMOGRAPHY [J].
BENTLEY, MD ;
LERMAN, LO ;
HOFFMAN, EA ;
FIKSENOLSEN, MJ ;
RITMAN, EL ;
ROMERO, JC .
CIRCULATION RESEARCH, 1994, 74 (05) :945-951
[5]   VALIDATION OF USE OF XE-133 TO MEASURE INTRARENAL DISTRIBUTION OF BLOOD FLOW [J].
BLAUFOX, MD ;
FROMOWITZ, A ;
GRUSKIN, A ;
MENG, CH ;
ELKIN, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 219 (02) :440-+
[6]   QUANTITATIVE-EVALUATION OF FUNCTIONAL RENAL VOLUME IN NORMAL-CHILDREN BASED ON [I-123] HIPPURAN-GAMMA CAMERA RENOGRAPHY [J].
CARLSEN, O ;
NATHAN, E .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1986, 19 (02) :119-136
[7]  
DAWSON P, 1993, INVEST RADIOL, V28, pS79
[8]  
DUNNILL M S, 1973, Journal of Pathology, V110, P113, DOI 10.1002/path.1711100202
[9]   KIDNEY SIZE IN CHILDREN - METHOD OF ASSESSMENT [J].
EKLOF, O ;
RINGERTZ, H .
ACTA RADIOLOGICA-DIAGNOSIS, 1976, 17 (NA5) :617-625
[10]   DETERMINATION OF LEFT-VENTRICULAR MASS IN DOGS WITH RAPID-ACQUISITION CARDIAC COMPUTED TOMOGRAPHIC SCANNING [J].
FEIRING, AJ ;
RUMBERGER, JA ;
REITER, SJ ;
SKORTON, DJ ;
COLLINS, SM ;
LIPTON, MJ ;
HIGGINS, CB ;
ELL, S ;
MARCUS, ML .
CIRCULATION, 1985, 72 (06) :1355-1364