Reproducibility of human kidney perfusion and volume determinations with electron beam computed tomography

被引:51
作者
Lerman, LO
Flickinger, AL
Sheedy, PF
Turner, ST
机构
[1] MAYO CLIN & MAYO FDN,DIV NEPHROL,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DIV HYPERTENS,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT RADIOL,ROCHESTER,MN 55905
关键词
renal circulation; renal volume; x-ray CT;
D O I
10.1097/00004424-199604000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Alterations in whole kidney, cortical, and medullary perfusion and volume play a pivotal role in various physiologic and pathophysiologic processes. Electron-beam computed tomography (EBCT) provides accurate measurements of these traits in animals, but their reproduciblity in humans has not been established. METHODS. Perfusion, volume, and flow measurements were obtained by EBCT in eight healthy human volunteers under controlled conditions on two consecutive days. RESULTS. Mean values for whole kidney, cortical, and medullary perfusion and volume obtained with EBCT were similar in scan 1 and scan 2 (P > 0.1), and correlated highly. Coefficients of variation for the repeated measurements usually were less than 14% Values obtained for renal regional perfusion and volume agreed with previously reported values. CONCLUSIONS. Electron-beam computed tomography estimates of single whole kidney, cortical, and medullary perfusions and volumes are highly reproducible in normal humans, and may be useful to advance understanding of renal involvement in human disease.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 52 条
[21]   USE OF A THERMODILUTION RENAL-VEIN CATHETER TO MEASURE RENAL BLOOD-FLOW IN PATIENTS WITH ESSENTIAL-HYPERTENSION [J].
KATO, T ;
SAKAMAKI, T ;
NAKAMURA, T ;
KUMAKURA, H ;
MATSUMOTO, M ;
ISHIZAKA, H ;
ICHIKAWA, S ;
ONO, Z ;
SATO, K ;
MURATA, K .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1994, 58 (04) :238-247
[22]   MEASUREMENT OF INTRARENAL BLOOD FLOW .1. ANALYSIS OF MICROSPHERE METHOD [J].
KATZ, MA ;
BLANTZ, RC ;
RECTOR, FC ;
SELDIN, DW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1971, 220 (06) :1903-&
[23]  
KAWAMURA J, 1984, EUR J NUCL MED, V9, P168, DOI 10.1007/BF00251465
[24]   UNILATERAL RENAL HEMODYNAMICS AND CHARACTERISTICS OF DYE-DILUTION CURVES IN PATIENTS WITH ESSENTIAL HYPERTENSION AND RENAL DISEASE [J].
KIOSCHOS, JM ;
KIRKENDALL, WM ;
VALENCA, MR ;
FITZ, AE .
CIRCULATION, 1967, 35 (02) :229-+
[25]   INTRARENAL DISTRIBUTION OF BLOOD-FLOW - EVOLUTION OF A NEW APPROACH TO MEASUREMENT [J].
KNOX, FG ;
RITMAN, EL ;
ROMERO, JC .
KIDNEY INTERNATIONAL, 1984, 25 (03) :473-479
[27]  
Lerman Lilach O., 1993, Journal of the American Society of Nephrology, V4, P582
[28]   PRESSURE DEPENDENCY OF CANINE INTRARENAL BLOOD-FLOW WITHIN THE RANGE OF AUTOREGULATION [J].
LERMAN, LO ;
BENTLEY, MD ;
FIKSENOLSEN, MJ ;
STRICK, DM ;
RITMAN, EL ;
ROMERO, JC .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 1995, 268 (03) :F404-F409
[29]   QUANTITATION OF THE INVIVO KIDNEY VOLUME WITH CINE COMPUTED-TOMOGRAPHY [J].
LERMAN, LO ;
BENTLEY, MD ;
BELL, MR ;
RUMBERGER, JA ;
ROMERO, JC .
INVESTIGATIVE RADIOLOGY, 1990, 25 (11) :1206-1211
[30]   QUANTIFICATION OF GLOBAL AND REGIONAL RENAL BLOOD-FLOW WITH ELECTRON-BEAM COMPUTED-TOMOGRAPHY [J].
LERMAN, LO ;
BELL, MR ;
LAHERA, V ;
RUMBERGER, JA ;
SHEEDY, PF ;
FUEYO, AS ;
ROMERO, JC .
AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (09) :829-837