Separation of chlorine-containing anions by ion chromatography and capillary electrophoresis

被引:27
作者
Biesaga, M
Kwiatkowska, M
Trojanowicz, M
机构
[1] INST NUCL CHEM & TECHNOL,PL-03195 WARSAW,POLAND
[2] WARSAW UNIV,DEPT CHEM,PL-02093 WARSAW,POLAND
[3] INST ENVIRONM PROTECT,PL-00548 WARSAW,POLAND
关键词
inorganic anions; chlorine-containing anions;
D O I
10.1016/S0021-9673(97)00338-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chlorine is still commonly used as disinfectant in water and waste treatment and as bleaching agents in the paper industry. In these processes, numerous chlorine-containing anions are formed with different oxidation states, such as chloride, chlorite, chlorate and perchlorate. The present study is focused on the development of a single-column ion chromatography (SCIC) method and the use of capillary electrophoresis (CE) for the determination of chlorine anions in water at a concentration level up to 25 mg/l for IC and 20 mg/l for CE in the presence of nitrate and sulphate. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 22 条
[1]   DIRECT AND SEQUENTIAL POTENTIOMETRIC DETERMINATION OF HYPOCHLORITE, CHLORITE, AND CHLORATE IONS WHEN HYPOCHLORITE ION IS PRESENT IN LARGE EXCESS [J].
ADAM, LC ;
GORDON, G .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :535-540
[2]  
BOLYARD M, 1992, ENVIRON SCI TECHNOL, V26, P1603
[3]   DETERMINATION OF CHLORITE AND CHLORATE IN CHLORINATED AND CHLORAMINATED DRINKING-WATER BY FLOW-INJECTION ANALYSIS AND ION CHROMATOGRAPHY [J].
DIETRICH, AM ;
LEDDER, TD ;
GALLAGHER, DL ;
GRABEEL, MN ;
HOEHN, RC .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :496-502
[4]   CLARIFICATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY [J].
FOLEY, JP ;
DORSEY, JG .
CHROMATOGRAPHIA, 1984, 18 (09) :503-511
[5]  
Foret F., 1993, CAPILLARY ZONE ELECT
[6]   ANALYSIS OF OXYHALIDE DISINFECTION BY-PRODUCTS AND OTHER ANIONS OF INTEREST IN DRINKING-WATER BY ION CHROMATOGRAPHY [J].
HAUTMAN, DP ;
BOLYARD, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :65-74
[7]   TABLE OF ISOTACHOPHORETIC INDEXES .1. SIMULATED QUALITATIVE AND QUANTITATIVE INDEXES OF 287 ANIONIC SUBSTANCES IN THE RANGE PH 3-10 [J].
HIROKAWA, T ;
NISHINO, M ;
AOKI, N ;
KISO, Y ;
SAWAMOTO, Y ;
YAGI, T ;
AKIYAMA, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 271 (02) :D1-D106
[8]   OPTIMIZATION OF DETECTION SENSITIVITY IN THE CAPILLARY ELECTROPHORESIS OF INORGANIC ANIONS [J].
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2) :431-443
[9]   VARIOUS APPROACHES TO ANALYSIS OF DIFFICULT SAMPLE MATRICES OF ANIONS USING CAPILLARY ION ELECTROPHORESIS [J].
JONES, WR ;
JANDIK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :385-393
[10]   CONTROLLED CHANGES OF SELECTIVITY IN THE SEPARATION OF IONS BY CAPILLARY ELECTROPHORESIS [J].
JONES, WR ;
JANDIK, P .
JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2) :445-458