Discerning matrix-cluster peaks in matrix-assisted laser desorption/ionization time-of-flight mass spectra of dilute peptide mixtures

被引:72
作者
Keller, BO [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S1044-0305(99)00126-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is widely used for the analysis of peptide mixtures such as those resulting from protein digestion. Among several useful peptide matrices, alpha-cyano-4-hydroxycinnamic acid (4-HCCA) appears to be the most popular. This matrix does not generally give matrix-cluster peaks at the mass region covered by enzyme-digested peptides (i.e., m/z above similar to 500). However, when an analyte mixture is very dilute and/or the sample contains a large amount of salts, ion peaks from matrix clusters can be quite intense, compared to peptide peaks. This matrix-cluster interference becomes more pronounced as the amount of analyte decreases. In this paper, a simple scheme for matrix-cluster identification is reported. It is shown that matrix-cluster formation follows a systematic pattern, although the relative intensities of these cluster ions cannot be predicted. Discerning the matrix-cluster peaks from the peptide peaks is found to be critical in analyzing dilute peptide mixtures with both conventional and microspot MALDI-TOF techniques. (J Am Soc Mass Spectrom 2000, 11, 88-93) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 20 条
[1]  
Allmaier G, 1997, RAPID COMMUN MASS SP, V11, P1567, DOI 10.1002/(SICI)1097-0231(199709)11:14<1567::AID-RCM32>3.0.CO
[2]  
2-0
[3]   ALPHA-CYANO-4-HYDROXYCINNAMIC ACID AS A MATRIX FOR MATRIX-ASSISTED LASER DESORPTION MASS-SPECTROMETRY [J].
BEAVIS, RC ;
CHAUDHARY, T ;
CHAIT, BT .
ORGANIC MASS SPECTROMETRY, 1992, 27 (02) :156-158
[4]   Two-layer sample preparation: A method for MALDI-MS analysis of complex peptide and protein mixtures [J].
Dai, YQ ;
Whittal, RM ;
Li, L .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1087-1091
[5]  
DAI YQ, 1996, ANAL CHEM, V68, P2721
[6]   On the mechanism and control of salt-induced resolution loss in matrix-assisted laser desorption/ionization [J].
Dubois, F ;
Knochenmuss, R ;
Steenvoorden, RJJM ;
Breuker, K ;
Zenobi, R .
EUROPEAN MASS SPECTROMETRY, 1996, 2 (2-3) :167-172
[7]  
Jungblut P, 1997, MASS SPECTROM REV, V16, P145, DOI 10.1002/(SICI)1098-2787(1997)16:3<145::AID-MAS2>3.0.CO
[8]  
2-H
[9]  
Kussmann M, 1997, J MASS SPECTROM, V32, P593
[10]   Analysis of single mammalian cell lysates by mass spectrometry [J].
Li, L ;
Golding, RE ;
Whittal, RM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (46) :11662-11663