Flow injection on-line solid phase extraction coupled with inductively coupled plasma mass spectrometry for determination of (ultra)trace rare earth elements in environmental materials using maleic acid grafted polytetrafluoroethylene fibers as sorbent

被引:47
作者
Wang, Zhao-Hui [1 ]
Yan, Xiu-Ping [1 ]
Wang, Zhi-Peng [1 ]
Zhang, Zheng-Pu [1 ]
Liu, Li-Wen [1 ]
机构
[1] Nankai Univ, Coll Chem, Res Ctr Analyt Sci, Minist Educ,Key Lab Funct Polymer Mat, Tianjin 300071, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1016/j.jasms.2006.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sorbent, maleic acid grafted polytetrafluoroethylene fiber (MA-PTFE), was prepared and evaluated for on-line solid-phase extraction coupled with inductively coupled plasma mass spectrometry (ICP-MS) for fast, selective, and sensitive determination of (ultra)trace rare earth elements (REEs) in environmental samples. The REEs in aqueous samples at pH = 3.0 were selectively extracted onto a microcolumn packed with the MA-PTFE fiber, and the adsorbed REEs were subsequently eluted on-line with 0.9 mol 1(-1) HNO3 for ICP-MS determination. The new sorbent extraction system allows effective preconcentration and separation of the REEs from the major matrix constituents of alkali and alkali earth elements, particularly their separation from barium that produces considerable isobaric interferences of (BaOH+)-Ba-134-O-16-H-1, (BaO+)-Ba-135-O-16,(BaOH+)-Ba-136-O-16-H-1, and (BaO+)-Ba-137-O-16 on Eu-151(+) and Eu-153(+). With the use of a sample loading flow rate of 7.4 ml min(-1) for 120 s preconcentration, enhancement factors of 69-97 and detection limits (3s) of 1-20 pg 1(-1) were achieved at a sample throughput of 22 samples h(-1). The precision (RSD) for 16 replicate determinations of 50 ng 1(-1) of REEs was 0.5-1.1%. The developed method was successfully applied to the determination of (ultra)trace REEs in sediment, soil, and seawater samples. (J Am Soc Mass Spectrom 2006,17, 1258-1264) (c) 2006 American Society for Mass Spectrometry.
引用
收藏
页码:1258 / 1264
页数:7
相关论文
共 29 条
[11]   Determination of rare earth elements in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Kajiya, T ;
Aihara, M ;
Honda, K ;
Shikino, O .
TALANTA, 2002, 58 (06) :1185-1194
[12]  
Humphris S., 1984, Rare Earth Element Geochemistry, Vol. 2, V2, P317, DOI [10.1016/b978-0-444-42148-7.50014-9, DOI 10.1016/B978-0-444-42148-7.50014-9]
[13]   Determination of rare earth elements in human blood serum by inductively coupled plasma mass spectrometry after chelating resin preconcentration [J].
Inagaki, K ;
Haraguchi, H .
ANALYST, 2000, 125 (01) :191-196
[14]  
JARVIES KE, 1992, HDB INDUCTIVELY COUP
[15]   Determination of rare earth elements in seawater by inductively coupled plasma mass spectrometry with on-line column pre-concentration using 8-quinolinole-immobilized fluorinated metal alkoxide glass [J].
Kajiya, T ;
Aihara, M ;
Hirata, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) :543-550
[16]   Collaborative study to improve the quality control of rare earth element determinations in environmental matrices [J].
Kramer, KJM ;
Dorten, WS ;
Van het Groenewoud, H ;
de Haan, E ;
Kramer, GN ;
Monteiro, L ;
Muntau, H ;
Quevauviller, P .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (01) :83-89
[17]   Improved detection of transition and rare earth elements in marine samples with the CETAC DSX-100 preconcentration/matrix elimination system and ICP-MS [J].
Kühn, M ;
Kriews, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (05) :440-444
[18]   ESR study on free radicals trapped in crosslinked polytetrafluoroethylene (PTFE) - II radical formation and reactivity [J].
Oshima, A ;
Seguchi, T ;
Tabata, Y .
RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (01) :61-71
[19]   Determination of rare earth elements U and Th in environmental samples by inductively coupled plasma double focusing sectorfield mass spectrometry (ICP-SMS) [J].
Prohaska, T ;
Hann, S ;
Latkoczy, C ;
Stingeder, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) :1-8
[20]   On-line and off-line preconcentration of trace and ultratrace amounts of lanthanides [J].
Rao, TP ;
Kala, R .
TALANTA, 2004, 63 (04) :949-959