Powder spectral density (PSD) was measured in steady flow conditions in continuous-wave (CW) and pulsed wave (PW) ultrasound Doppler mode. The estimated PSD of the Doppler backscattered signal showed discrepancies from the expected value which was more severe in the PW mode than in the CW mode. Intrinsic spectral broadening (ISB) was significantly larger in PW mode than in the CW mode. Interpretation of Doppler PSD measurement results required caution. Artefacts due to intrinsic random effects related to standard signal manipulations and experimental conditions were severe and mode-dependent, and significantly affected the estimated flow parameters.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 12 条
[1]   CALCULATION OF DOPPLER SPECTRAL POWER-DENSITY FUNCTIONS [J].
ALDIS, GK ;
THOMPSON, RS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (10) :1022-1031
[2]  
EVANS HD, 1989, DOPPLER ULTRASOUND P, P206
[3]   MEASUREMENT OF FLUID TURBULENCE BASED ON PULSED ULTRASOUND TECHNIQUES .1. ANALYSIS [J].
GARBINI, JL ;
FORSTER, FK ;
JORGENSEN, JE .
JOURNAL OF FLUID MECHANICS, 1982, 118 (MAY) :445-470
[4]   COMPUTER-CONTROLLED POSITIVE DISPLACEMENT PUMP FOR PHYSIOLOGICAL FLOW SIMULATION [J].
HOLDSWORTH, DW ;
RICKEY, DW ;
DRANGOVA, M ;
MILLER, DJM ;
FENSTER, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (06) :565-570
[5]   A COMPUTER-CONTROLLED FLOW PHANTOM FOR GENERATION OF PHYSIOLOGICAL DOPPLER WAVEFORMS [J].
HOSKINS, PR ;
ANDERSON, T ;
MCDICKEN, WN .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (11) :1709-1717
[6]   A UNIFIED APPROACH TO MODELING THE BACKSCATTERED DOPPLER ULTRASOUND FROM BLOOD [J].
MO, LYL ;
COBBOLD, RSC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (05) :450-461
[7]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[8]   THE DEPENDENCE OF ULTRASOUND DOPPLER BANDWIDTH ON BEAM GEOMETRY [J].
NEWHOUSE, VL ;
FURGASON, ES ;
JOHNSON, GF ;
WOLF, DA .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1980, 27 (02) :50-59
[9]   ANALYSIS OF TRANSIT-TIME EFFECTS ON DOPPLER FLOW MEASUREMENT [J].
NEWHOUSE, VL ;
BENDICK, PJ ;
VARNER, LW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (05) :381-387
[10]  
Oppenheim AV, 1975, DIGITAL SIGNAL PROCE