An experimental study of the failure modes of the gamma locking nail and AO dynamic hip screw under static loading: a cadaveric study

被引:56
作者
Haynes, RC
Poll, RG
Miles, AW
Weston, RB
机构
[1] UNIV BATH, SCH MECH ENGN, BATH BA2 7AY, AVON, ENGLAND
[2] ACAD HOSP LEIDEN, DEPT ORTHOPAED SURG, LEIDEN, NETHERLANDS
关键词
biomechanics; cadaveric; hip fracture; failure;
D O I
10.1016/S1350-4533(97)00003-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The sliding compression screw is widely regarded as the optimum treatment for intertrochanteric fractures of the femur; allowing bone fragments to impact until a bony support has been established across the fracture site. This study carried out biomechanical, cadaveric tests to establish the influence of direct static loading situations on the modes of failure of the Gamma Nail compared with the Dynamic Hip Screw (DHS). Clinical studies report DHS failures of lag screws cutting-out, bending of the lag screws and cortical screws pulling out causing plate loosening. Gamma Gamma Nail failures include lag screw cut-out or fractures of the femoral shaft around the the distal locking screws or nail tip. In this study each failure mode has been isolated, to establish the loads to failure under various fracture configurations. The biomechanical results indicated that the intramedullary Gamma Locking Nail can be recommended over a standard DHS in over a standard DHS in cases of subtrochanteric fracture or conditions of very poor bone quality. (C) 1997 IPEM. Published by Elsevier Science Ltd.
引用
收藏
页码:446 / 453
页数:8
相关论文
共 23 条
[1]
BORIANI S, 1991, ORTHOPEDICS, V14, P1307
[2]
FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[3]
THE GAMMA-NAIL - A SIGNIFICANT ADVANCE OR A PASSING FASHION [J].
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :329-331
[4]
INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[5]
EBERLE C, 1993, HELV CHIR ACTA, V59, P527
[6]
GOLDHAGEN PR, 1993, J ORTHROP TRAUMA, V7, P193
[7]
GUYER P, 1991, Aktuelle Traumatologie, V21, P242
[8]
THE GAMMA-NAIL FOR PERITROCHANTERIC FRACTURES [J].
HALDER, SC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :340-344
[9]
HOGH J, 1993, J BONE JT SURG B S2, V75
[10]
UNSTABLE TROCHANTERIC FRACTURES TREATED WITH SLIDING SCREW-PLATE SYSTEM - BIOMECHANICAL STUDY OF UNSTABLE TROCHANTERIC FRACTURES .3. [J].
JENSEN, JS ;
TONDEVOLD, E ;
MOSSING, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (04) :392-397