MR imaging with ultrasmall superparamagnetic iron oxide particles in experimental soft-tissue infections in rats

被引:66
作者
Kaim, AH
Wischer, T
O'Reilly, T
Jundt, G
Fröhlich, J
von Schulthess, GK
Allegrini, PR
机构
[1] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Basel Hosp, Dept Diagnost Radiol, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Dept Pathol, CH-4031 Basel, Switzerland
[4] Novartis Pharma, Basel, Switzerland
[5] Guerbet, Zurich, Switzerland
关键词
animals; contrast media; experimental studies; iron; magnetic resonance (MR); soft tissues; infection;
D O I
10.1148/radiol.2253011485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the feasibility of macrophage magnetic resonance (MR) imaging in rats by using an experimental soft-tissue infection model. MATERIALS AND METHODS: Thirteen rats with unilateral calf-muscle infection were imaged with a 4.7-T MR imager at an early chronic stage of infection (day 4 before contrast material injection, days 4-7 after injection). Eleven animals were imaged before and 3 and 24 hours after intravenous application of ultrasmall superparamagnetic iron oxide (USPIO), and eight animals were additionally imaged 48 hours and three animals 72 hours after USPIO application. Two infected rats served as controls. T1- and T2-weighted spin-echo and T2*-weighted gradient-echo sequences were applied. All animals were sacrificed, and histopathologic findings were correlated with findings on MR images. Electron microscopy was performed in two rats. For quantitative analysis, signal intensities on T2*-weighted images and T2 values on T2 maps were measured within regions of interest, and the temporal variation was analyzed by using the signed rank test. RESULTS: Visualization of USPIO-loaded macrophages was most sensitive with a T2*-weighted sequence. USPIO distribution pattern and quantitative analysis of T2 and T2* effects 3 hours after USPIO application were significantly different (P < .05) from those at 24 and 48 hours, reflecting the dynamic transit of the particle accumulation from the intravascular to the intracellular compartment by means of macrophage phagocytosis. Local signal intensity alterations could be correlated with iron-loaded macrophages at histopathologic examination. CONCLUSION: Activated macrophages in acute soft-tissue infection can be labeled with USPIOs and detected with MR imaging because of susceptibility effects. (C) RSNA, 2002.
引用
收藏
页码:808 / 814
页数:7
相关论文
共 34 条
[21]  
Madri J, 1990, ANDERSONS PATHOL, V1, P67
[22]   Uptake of dextran-coated monocrystalline iron oxides in tumor cells and macrophages [J].
Moore, A ;
Weissleder, R ;
Bogdanov, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (06) :1140-1145
[23]  
Rausch M, 2001, MAGNET RESON MED, V46, P1018, DOI 10.1002/mrm.1290
[24]  
RITCHIE AC, 1990, BOYDS TXB PATHOLOGY, V1, P60
[25]  
Ruehm SG, 2001, CIRCULATION, V103, P415
[26]   Bone contusion patterns of the knee at MR imaging: Footprint of the mechanism of injury [J].
Sanders, TG ;
Medynski, MA ;
Feller, JF ;
Lawhorn, KW .
RADIOGRAPHICS, 2000, 20 :S135-S151
[27]  
Seligson D, 1999, CLIN ORTHOP RELAT R, P30
[28]   BONE-MARROW - ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE FOR MR IMAGING [J].
SENETERRE, E ;
WEISSLEDER, R ;
JARAMILLO, D ;
REIMER, P ;
LEE, AS ;
BRADY, TJ ;
WITTENBERG, J .
RADIOLOGY, 1991, 179 (02) :529-533
[29]   Superparamagnetic iron oxide particles (SH U 555 A): Evaluation of efficacy in three doses for hepatic MR imaging [J].
Shamsi, K ;
Balzer, T ;
Saini, S ;
Ros, PR ;
Nelson, RC ;
Carter, EC ;
Tollerfield, S ;
Niendorf, HP .
RADIOLOGY, 1998, 206 (02) :365-371
[30]   ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - CHARACTERIZATION OF A NEW CLASS OF CONTRAST AGENTS FOR MR IMAGING [J].
WEISSLEDER, R ;
ELIZONDO, G ;
WITTENBERG, J ;
RABITO, CA ;
BENGELE, HH ;
JOSEPHSON, L .
RADIOLOGY, 1990, 175 (02) :489-493