Patch testing with components of water-based metalworking fluids:: results of a multicentre study with a second series

被引:25
作者
Geier, Johannes
Lessmann, Holger
Becker, Detlef
Bruze, Magnus
Frosch, Peter J.
Fuchs, Thomas
Jappe, Uta
Koch, Patrick
Pfoehler, Claudia
Skudlik, Christoph
机构
[1] Univ Gottingen, Informat Network Dept Dermatol IVDK, D-37075 Gottingen, Germany
[2] Univ Mainz, Dept Dermatol, D-6500 Mainz, Germany
[3] Lund Univ, Dept Occupat & Environm Dermatol, S-20502 Malmo, Sweden
[4] Univ Witten Herdecke, D-44137 Dortmund, Germany
[5] Klinikum Dortmund, Dept Dermatol, D-44137 Dortmund, Germany
[6] Univ Gottingen, Dept Dermatol, D-37075 Gottingen, Germany
[7] Univ Heidelberg, Dept Dermatol, D-69115 Heidelberg, Germany
[8] Univ Saarland, Dept Dermatol, D-66421 Homburg, Germany
[9] Univ Osnabruck, Dept Dermatol Environm Med & Hlth Theory, D-49069 Osnabruck, Germany
关键词
2-amino-2-ethyl-1,3-propanediol (AEPD); 1-amino-2-propanol (monoisopropanolamine; MIPA); contact allergy; formaldehyde; metalworking fluids; 4,4 '-methylenebis morpholine; myristyl alcohol; occupational; patch testing;
D O I
10.1111/j.1600-0536.2006.00993.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Although many allergens in metalworking fluids (MWF) are identified, there are still some MWF components, which are not sufficiently investigated concerning their sensitizing properties. Objectives: To investigate sensitization to 10 frequently used MWF components, which are not part of the established MWF test series, in metalworkers with suspected occupational dermatitis due to MWF. Patients/Methods: Oleyl alcohol, myristyl alcohol, dimethylolurea, 4,4'-methylenebis morpholine, imazalil, 1-amino-2-propanol (monoisopropanolamine; MIPA), 2-amino-2-ethyl-1,3-propanediol (AEPD), 2,5-bis(n-octyldithio)-1,3,4-thiadiazole, zinc alkyl dithiophosphate and dibenzyl disulfide have been patch tested in 144 patients. Results: 7 patients reacted positively to the formaldehyde releaser 4,4'-methylenebis morpholine, and 6 of these patients also reacted to formaldehyde and/or other formaldehyde releasers. 4 patients reacted positively to myristyl alcohol tested at 10% petrolatum (pet.). Additionally, 20 doubtful or irritant reactions occurred. 1 patient each reacted positively to oleyl alcohol, MIRA, and AEPD. None of the other test substances mentioned above elicited any clear-cut positive reaction. Patch testing with well-known MWF allergens showed proportions of positive reactions, which were comparable to those from other studies, e.g. 11% to monoethanolamine, 8% to colophonium and 3%-5% to various preservatives. Conclusions: 4,4'-methylenebis morpholine may be an important MWF allergen, although clinical relevance could not be stated definitely in every case. Myristyl alcohol should not be patch tested at 10% pet., but at a lesser concentration, due to irritant properties.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 33 条
[1]  
BEYER KH, 1987, J AM COLL TOXICOL, V6, P53
[2]  
BRUZE M, UNPUB FALSE NEGATIVE
[3]  
de Groot A., 1994, PATCH TESTING TEST C
[4]   COSMETIC ALLERGY FROM MYRISTYL ALCOHOL [J].
DEGROOT, AC ;
BRUYNZEEL, DP ;
VANJOOST, T ;
WEYLAND, JW .
CONTACT DERMATITIS, 1988, 19 (01) :76-77
[5]  
Foulds IS, 2000, HDB OCCUPATIONAL DER, P691, DOI [10.1007/978-3-662-07677-4_86, DOI 10.1007/978-3-662-07677-4_86]
[6]   Contact sensitizations in metalworkers with occupational dermatitis exposed to water-based metalworking fluids: results of the research project "FaSt" [J].
Geier, J ;
Lessmann, H ;
Schnuch, A ;
Uter, W .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2004, 77 (08) :543-551
[7]   Patch test results with the metalworking fluid series of the German Contact Dermatitis Research Group (DKG) [J].
Geier, J ;
Lessmann, H ;
Dickel, H ;
Frosch, PJ ;
Koch, P ;
Becker, D ;
Jappe, U ;
Aberer, W ;
Schnuch, A ;
Uter, W .
CONTACT DERMATITIS, 2004, 51 (03) :118-130
[8]   Patch testing with components of water-based metalworking fluids [J].
Geier, J ;
Lessmann, H ;
Frosch, PJ ;
Pirker, C ;
Koch, P ;
Aschoff, R ;
Richter, G ;
Becker, D ;
Eckert, C ;
Uter, W ;
Schnuch, A ;
Fuchs, T .
CONTACT DERMATITIS, 2003, 49 (02) :85-90
[9]   The positivity ratio - another parameter to assess the diagnostic quality of a patch test preparation [J].
Geier, J ;
Uter, W ;
Lessmann, H ;
Schnuch, A .
CONTACT DERMATITIS, 2003, 48 (05) :280-282
[10]  
Geier J., 2000, DERMATOL BERUF UMWEL, V48, P232