Detection and characterization of intracardiac thrombi on MR imaging

被引:109
作者
Barkhausen, J
Hunold, P
Eggebrecht, H
Schüler, WO
Sabin, GV
Erbel, R
Debatin, JF
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Cardiol, D-45122 Essen, Germany
[3] Elisabeth Hosp Essen, Dept Cardiol, D-45138 Essen, Germany
关键词
D O I
10.2214/ajr.179.6.1791539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of our study was to compare the diagnostic accuracy achieved using different MR techniques with the diagnostic accuracy achieved using transthoracic and transesophageal echocardiography to detect intracardiac thrombi. MATERIALS AND METHODS. Twenty-four patients with known or suspected intracardiac thrombi were examined using MR imaging and echocardiography. All MR examinations were performed on a 1.5-T MR scanner using dark-blood-prepared half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences, fast imaging steady-state free precession (trueFISP) cine sequences, and inversion recovery gradient-echo fast low-angle-shot (inversion recovery turbo FLASH) sequences after injection of 0.2 mmol/kg of gadolinium diethylene triamine pentaacetic acid. RESULTS. MR imaging and echocardiography revealed 12 thrombi-two in the right atrium, one in the right ventricle, three in the left atrium, and six in the left ventricle. Compared with echocardiography, MR imaging revealed three additional thrombi in the left ventricle; these thrombi were confirmed at surgery. All 15 thrombi appeared as filling defects on early contrast-enhanced inversion recovery turbo FLASH MR images. Only seven thrombi were detected on HASTE images, and 10 thrombi were seen on trueFISP images. Four thrombi showed enhancement 10-20 min after contrast material injection and were characterized as organized clots. CONCLUSION. Contrast-enhanced inversion recovery turbo FLASH sequences were superior to dark-blood-prepared HASTE and trueFISP cine MR images in revealing intracardiac thrombi. Compared with transthoracic echocardiography, MR imaging was more sensitive for the detection of left ventricular thrombi. The characterization of thrombi may be used to predict the risk of embolism, which is higher for subacute clots than for organized thrombi.
引用
收藏
页码:1539 / 1544
页数:6
相关论文
共 28 条
[1]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[2]   THE LAUSANNE STROKE REGISTRY - ANALYSIS OF 1,000 CONSECUTIVE PATIENTS WITH 1ST STROKE [J].
BOGOUSSLAVSKY, J ;
VANMELLE, G ;
REGLI, F .
STROKE, 1988, 19 (09) :1083-1092
[3]   Prevalence and prognostic significance of right-sided cardiac mobile thrombi in acute massive pulmonary embolism [J].
Casazza, F ;
Bongarzoni, A ;
Centonze, F ;
Morpurgo, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10) :1433-&
[4]   Floating right heart thrombi and pulmonary embolism: Diagnosis, outcome and therapeutic management [J].
Chapoutot, L ;
Nazeyrollas, P ;
Metz, D ;
Maes, D ;
Maillier, B ;
Jennesseaux, C ;
Elaerts, J .
CARDIOLOGY, 1996, 87 (02) :169-174
[5]   Free-floating thrombi in the right heart -: Diagnosis, management, and prognostic indexes in 38 consecutive patients [J].
Chartier, L ;
Béra, J ;
Delomez, M ;
Asseman, P ;
Beregi, JP ;
Bauchart, JJ ;
Warembourg, H ;
Théry, C .
CIRCULATION, 1999, 99 (21) :2779-2783
[6]   MEDICAL PROGRESS - TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
DANIEL, WG ;
MUGGE, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (19) :1268-1279
[7]  
De Cock C, 1998, J HEART VALVE DIS, V7, P668
[8]   REVIEW OF ECHOCARDIOGRAPHICALLY DIAGNOSED RIGHT HEART ENTRAPMENT OF PULMONARY EMBOLI-IN-TRANSIT WITH EMPHASIS ON MANAGEMENT [J].
FARFEL, Z ;
SHECHTER, M ;
VERED, Z ;
RATH, S ;
GOOR, D ;
GAFNI, J .
AMERICAN HEART JOURNAL, 1987, 113 (01) :171-178
[9]  
Fujita N, 1994, Am J Card Imaging, V8, P69
[10]   CARDIAC TUMORS - ASSESSMENT WITH GD-DTPA ENHANCED MR IMAGING [J].
FUNARI, M ;
FUJITA, N ;
PECK, WW ;
HIGGINS, CB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) :953-958