Long-Term Impact of Right Ventricular Septal Versus Apical Pacing on Left Ventricular Synchrony and Function in Patients With Second- or Third-Degree Heart Block

被引:89
作者
Arnold, C. T. [1 ]
Allman, Christine [1 ]
Vidaic, Jane [1 ]
Tie, Hui [1 ]
Hopkins, Andrew P. [1 ]
Leung, Dominic Y. [1 ]
机构
[1] Univ New S Wales, Liverpool Hosp, Dept Cardiol, Sydney, NSW, Australia
关键词
IDIOPATHIC DILATED CARDIOMYOPATHY; CARDIAC RESYNCHRONIZATION THERAPY; SICK-SINUS SYNDROME; ATRIAL-FIBRILLATION; OUTFLOW TRACT; QRS DURATION; FAILURE SECONDARY; RANDOMIZED-TRIAL; ECHOCARDIOGRAPHY; DYSSYNCHRONY;
D O I
10.1016/j.amjcard.2008.12.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Right ventricular (RV) septal pacing has been advocated as an alternative to apical pacing to avoid long-term detrimental effects. There is conflicting evidence on the benefits of RV septal pacing. Fifty-five subjects (22 normal healthy controls, 17 with RV septal pacing, and 17 with apical pacing) were recruited. Midventricular short-axis left ventricular (LV) circumferential and radial strains were determined. Circumferential and radial strain dyssynchrony and longitudinal systolic dyssynchrony were determined. Echocardiographic determination of pacing sites were compared with electrocardiogram and chest x-ray. Septal pacing is a heterogenous group of different pacing sites, and there was only modest agreement among echocardiogram, electrocardiogram, and chest x-ray. Median pacing durations were 436 days for septal pacing and 2,398 days for apical pacing. Mean QRS duration for apical pacing was longest, followed by septal pacing and control (p <0.001). LV mass index, end-systolic volume index, and ejection fraction were more impaired in septal than in apical pacing (all p values <0.05). Septal pacing was associated with more impaired circumferential strain (p <0.001) and worse LV dyssynchrony than apical pacing and control. In conclusion, standard fluoroscopic and electrocardiographic implantation techniques for RV septal pacing resulted in a heterogenous group of different pacing sites. This heterogenous RV septal pacing group was associated with poorer long-term LV function and greater dyssynchrony than RV apical pacing and control. (C) 2009 Elsevier Inc. (Am J Cardiol 2009;103:1096-1101)
引用
收藏
页码:1096 / 1101
页数:6
相关论文
共 30 条
  • [1] PROSPECTIVE RANDOMIZED TRIAL OF ATRIAL VERSUS VENTRICULAR PACING IN SICK-SINUS SYNDROME
    ANDERSEN, HR
    THUESEN, L
    BAGGER, JP
    VESTERLUND, T
    THOMSEN, PEB
    [J]. LANCET, 1994, 344 (8936) : 1523 - 1528
  • [2] Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome
    Andersen, HR
    Nielsen, JC
    Thomsen, PEB
    Thuesen, L
    Mortensen, PT
    Vesterlund, T
    Pedersen, AK
    [J]. LANCET, 1997, 350 (9086) : 1210 - 1216
  • [3] Relationship between QRS duration and left ventricular dyssynchrony in patients with end-stage heart failure
    Bleeker, GB
    Schalij, MJ
    Molhoek, SG
    Verwey, HF
    Holman, ER
    Boersma, E
    Steendijk, P
    Van Der Wall, EE
    Bax, JJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (05) : 544 - 549
  • [4] Evolution of ventricular function during permanent pacing from either right ventricular apex or outflow tract following AV-junctional ablation for atrial fibrillation
    Bourke, JP
    Hawkins, T
    Keavey, P
    Tynan, M
    Jamieson, S
    Behulova, R
    Furniss, SS
    [J]. EUROPACE, 2002, 4 (03): : 219 - 228
  • [5] Systolic and diastolic function with alternate and combined site pacing in the right ventricle
    Buckingham, TA
    Candinas, R
    Attenhofer, C
    Van Hoeven, H
    Hug, R
    Hess, O
    Jenni, R
    Amann, FW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (05): : 1077 - 1084
  • [6] Acute hemodynamic effects of atrioventricular pacing at differing sites in the right ventricle individually and simultaneously
    Buckingham, TA
    Candinas, R
    Schlapfer, J
    Aebischer, N
    Jeanrenaud, X
    Landolt, J
    Kappenberger, L
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (04): : 909 - 915
  • [7] Comparison of right ventricular outflow tract and apical lead permanent pacing on cardiac output
    Giudici, MC
    Thornburg, GA
    Buck, DAL
    Coyne, EP
    Walton, MC
    Paul, DL
    Sutton, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02) : 209 - &
  • [8] Acute hemodynamic effects of right ventricular pacing site and pacing mode in patients with congestive heart failure secondary to either ischemic or idiopathic dilated cardiomyopathy
    Gold, MR
    Brockman, R
    Peters, RW
    Olsovsky, MR
    Shorofsky, SR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (09) : 1106 - 1109
  • [9] The acute hemodynamic effects of right ventricular septal pacing in patients with congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy
    Gold, MR
    Shorofsky, SR
    Metcalf, MD
    Feliciano, Z
    Fisher, ML
    Gottlieb, SS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (05) : 679 - 681
  • [10] Comparative left ventricular function following atrial, septal, and apical single chamber heart pacing in the young
    Karpawich, PP
    Mital, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 1983 - 1988