Multiplexed colorimetric solid-phase extraction: Determination of silver(I), nickel(II), and sample pH

被引:35
作者
Gazda, DB
Fritz, JS
Porter, MD [1 ]
机构
[1] US DOE, Ames Lab, Inst Combinatorial Discovery, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
关键词
D O I
10.1021/ac049449r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the design and ground-based testing of a multiplexed colorimetric solid-phase extraction (MC-SPE) platform for the rapid determination of multiple water quality parameters in a simple set of operational steps. Colorimetric solid-phase extraction (C-SPE) is an analytical platform that combines impregnated colorimetric reagents on a solid-phase extraction membrane and diffuse reflectance spectroscopy to quantify trace analytes in water. In extending C-SPE to MC-SPE, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple syringes have been designed, enabling the simultaneous determination of three different measures of water quality. Separate, single-parameter membranes, placed in a read-out cartridge create unique, parameter-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. Performance evaluations of the MC-SPE platform were conducted using sample pH, silver(I), and nickel(II). Determinations of silver(I) (0.05-0.5 ppm) and nickel(II) (1.8-5.0 ppm) follow established C-SPE methods on reversed-phase extraction membranes using 5-(p-dimethylaminobenzylidene)rhodanine and dimethylglyoxime, respectively, as colorimetric reagents. Sample pH (2.5-5.0) is measured using an anion-exchange membrane impregnated with fluorescein. These determinations require similar to120 s to complete using a total sample volume of 3.0 mL. The extension of MC-SPE to the determination of a greater number of analytes and its potential application to space and earth-bound monitoring needs are briefly discussed.
引用
收藏
页码:4881 / 4887
页数:7
相关论文
共 22 条
[1]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[2]   Rapid, low level determination of silver(I) in drinking water by colorimetric-solid-phase extraction [J].
Arena, MP ;
Porter, MD ;
Fritz, JS .
ANALYTICA CHIMICA ACTA, 2003, 482 (02) :197-207
[3]   Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy [J].
Arena, MP ;
Porter, MD ;
Fritz, JS .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :185-190
[4]  
ARENA MP, 2002, 2002012535 SAE
[5]  
Blitz JP, 1998, TECH ANAL CHEM SER, P185
[6]   CHEMICAL SENSORS FOR BEDSIDE MONITORING OF CRITICALLY ILL PATIENTS [J].
COLLISON, ME ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :A425-&
[8]   Rapid determination of ions by combined solid-phase extraction-diffuse reflectance spectroscopy [J].
Fritz, JS ;
Arena, MP ;
Steiner, SA ;
Porter, MD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) :41-50
[9]   Investigation of the iodine-poly(vinylpyrrolidone) interaction employed in the determination of biocidal iodine by colorimetric solid-phase extraction [J].
Gazda, DB ;
Lipert, RJ ;
Fritz, JS ;
Porter, MD .
ANALYTICA CHIMICA ACTA, 2004, 510 (02) :241-247
[10]   Determination of nickel(II) as the nickel dimethylglyoxime complex using colorimetric solid phase extraction [J].
Gazda, DB ;
Fritz, JS ;
Porter, MD .
ANALYTICA CHIMICA ACTA, 2004, 508 (01) :53-59