Assessment of Myocardial Viability with 3D MRI at 3 T

被引:14
作者
Bauner, Kerstin U. [1 ]
Muehling, Olaf [2 ]
Theisen, Daniel [1 ]
Hayes, Carmel [3 ]
Wintersperger, Bernd J. [1 ]
Reiser, Maximilian F. [1 ]
Huber, Armin M. [1 ]
机构
[1] Univ Munich, Univ Hosp, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Univ Hosp, Dept Cardiol, D-81377 Munich, Germany
[3] Siemens Med Solut, Cardiovasc MRI, Erlangen, Germany
关键词
3D imaging; 3; T; cardiac imaging; MRI; viability; IRREVERSIBLE INJURY; INITIAL-EXPERIENCE; 3.0; TESLA; INFARCTION; ENHANCEMENT; DYSFUNCTION; HEART; RECONSTRUCTION; TRUEFISP; COIL;
D O I
10.2214/AJR.08.1394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The aim of our study was to show that spatial resolution can be improved without loss of diagnostic accuracy if a 3D inversion recovery gradient-recalled echo (GRE) sequence is used instead of a segmented inversion recovery GRE at 3 T for the assessment of myocardial infarction. SUBJECTS AND METHODS. Fifteen patients with myocardial infarction were examined on a 3-T MR system. A segmented breath-hold 3D inversion recovery GRE technique with a voxel size of 6.3 mm(3) was compared with a breath-hold standard 2D inversion recovery GRE technique with a voxel size of 21.3 mm(3) for the detection of delayed enhancement. Contrast-to-noise ratios (CNRs) were calculated and infarct volumes were measured. Detection and transmural extent of infarctions were evaluated using kappa statistics. Total acquisition times were measured for both sequences. RESULTS. The CNR in the 3D technique did not show any significant difference compared with the 2D technique. The correlation coefficients of the infarct volumes determined with the 3D and 2D inversion recovery GRE studies at 3 T were r = 0.99 (p < 0.001). The assessment of the presence of hyperenhanced myocardium in all segments and the evaluation of transmurality resulted in very good agreement (kappa = 0.98 and kappa = 0.90). Total acquisition time was significantly shorter with the 3D technique (2.4 +/- 0.9 minutes) than with the 2D technique (4.9 +/- 1.5 minutes) (p < 0.001). CONCLUSION. The use of a 3D inversion recovery GRE sequence at 3 T allows accurate assessment of myocardial infarction without loss of CNR compared with the standard 2D technique. Furthermore, data acquisition time can be significantly reduced.
引用
收藏
页码:1645 / 1650
页数:6
相关论文
共 34 条
[1]
Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla [J].
Bauner, Kerstin U. ;
Muehling, Olaf ;
Wintersperger, Bernd J. ;
Winnik, Eva ;
Reiser, Maximilian F. ;
Huber, Armin .
INVESTIGATIVE RADIOLOGY, 2007, 42 (06) :361-371
[2]
Gadolinium cardiovascular magnetic resonance predicts reversible myocardial dysfunction and remodeling in patients with heart failure undergoing β-blocker therapy [J].
Bello, D ;
Shah, DJ ;
Farah, GM ;
Di Luzio, S ;
Parker, M ;
Johnson, MR ;
Cotts, WG ;
Klocke, FJ ;
Bonow, RO ;
Judd, RM ;
Gheorghiade, M ;
Kim, RJ .
CIRCULATION, 2003, 108 (16) :1945-1953
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Cerqueira MD, 2002, INT J CARDIOVAS IMAG, V18, P539
[5]
Irreversible myocardial injury: Assessment with cardiovascular delayed-enhancement MR imaging and comparison of 1.5 and 3.0 T - Initial experience [J].
Cheng, Adrian S. H. ;
Robson, Matthew D. ;
Neubauer, Stefan ;
Selvanayagam, Joseph B. .
RADIOLOGY, 2007, 242 (03) :735-742
[6]
Comparison of the extent of dielayed-enhancement cardiac magnetic resonance imaging with and without phase-sensitive reconstruction at 3.0 T [J].
Cochet, Alexandre ;
Lalande, Alain ;
Walker, Paul M. ;
Boichot, Christophe ;
Ciappuccini, Renaud ;
Cottin, Yves ;
Wolf, Jean-Eric ;
Brunotte, Francois .
INVESTIGATIVE RADIOLOGY, 2007, 42 (06) :372-376
[7]
STRUCTURAL AND METABOLIC CORRELATES OF THE REVERSIBILITY OF CHRONIC LEFT-VENTRICULAR ISCHEMIC DYSFUNCTION IN HUMANS [J].
DEPRE, C ;
VANOVERSCHELDE, JLJ ;
MELIN, JA ;
BORGERS, M ;
BOL, A ;
AUSMA, J ;
DION, R ;
WIJNS, W .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (03) :H1265-H1275
[8]
Myocardial viability: Assessment with three-dimensional MR imaging in pigs and patients [J].
Dewey, M ;
Laule, M ;
Taupitz, M ;
Kaufels, N ;
Hamm, B ;
Kivelitz, D .
RADIOLOGY, 2006, 239 (03) :703-709
[9]
Assessment of myocardial infarction in pigs using a rapid clearance blood pool contrast medium [J].
Dewey, M ;
Kaufels, N ;
Laule, M ;
Schnorr, J ;
Wagner, S ;
Kivelitz, D ;
Raynaud, JS ;
Robert, P ;
Hamm, B ;
Taupitz, M .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) :703-709
[10]
Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385