High-frequency oscillatory ventilation for the prevention of chronic lung disease of prematurity

被引:226
作者
Johnson, AH
Peacock, JL
Greenough, A
Marlow, N
Limb, ES
Marston, L
Calvert, SA
机构
[1] Univ London St Georges Hosp, Dept Child Hlth, Sch Med, London SW17 0QT, England
[2] Univ London St Georges Hosp, Dept Publ Hlth Sci, Sch Med, London SW17 0QT, England
[3] Kings Coll Hosp London, Dept Child Hlth, Sch Med, London, England
[4] Univ Nottingham, Acad Div Child Hlth, Sch Human Dev, Nottingham NG7 2RD, England
关键词
D O I
10.1056/NEJMoa020432
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There remains uncertainty concerning the safety and efficacy of high-frequency oscillatory ventilation as compared with those of conventional ventilation for the respiratory support of very preterm infants. We conducted a multicenter trial to determine whether early intervention with high-frequency oscillatory ventilation reduced mortality and the incidence of chronic lung disease among newborns with a gestational age of 28 weeks or less. Methods We randomly assigned preterm infants with a gestational age of :23 to 28 weeks to either conventional ventilation or high-frequency oscillatory ventilation within one hour after birth. Randomization was stratified according to center and gestational age (23 to 25 weeks or 26 to 28 weeks). Results A total of 400 infants were assigned to high-frequency oscillatory ventilation, and 397 were assigned to conventional ventilation. The composite primary outcome (death or chronic lung disease, diagnosed at 36 weeks of postmenstrual age) occurred in 66 percent of the infants assigned to receive high-frequency oscillatory ventilation and 68 percent of those in the conventional-ventilation group (relative risk in the group assigned to high-frequency oscillatory ventilation, 0.98; 95 percent confidence interval, 0.89 to 1.08). Similar proportions of infants died or had chronic lung disease in each gestational-age group. In both treatment groups treatment failure occurred in 10 percent of infants (relative risk in the group assigned to high-frequency oscillatory ventilation, 0.99; 95 percent confidence interval, 0.66 to 1.50). There were no significant differences between the groups in a range of other secondary outcome measures, including serious brain injury and air leak. Conclusions The results obtained with high-frequency oscillatory ventilation and conventional ventilation do not differ significantly in the early treatment of respiratory disease in Very preterm infants. Assessment of long-term effects will require additional follow-up.
引用
收藏
页码:633 / 642
页数:10
相关论文
共 21 条
[1]   MULTIPLE SIGNIFICANCE TESTS - THE BONFERRONI METHOD .10. [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6973) :170-170
[2]  
BRYAN AC, 1991, PEDIATRICS, V87, P565
[3]  
CLARK RH, 1992, PEDIATRICS, V89, P5
[4]  
Courtney Sherry E., 2001, Pediatric Research, V49, p387A
[5]   VENTILATORY MANAGEMENT OF INFANT BABOONS WITH HYALINE-MEMBRANE DISEASE - THE USE OF HIGH-FREQUENCY VENTILATION [J].
DELEMOS, RA ;
COALSON, JJ ;
GERSTMANN, DR ;
NULL, DM ;
ACKERMAN, NB ;
ESCOBEDO, MB ;
ROBOTHAM, JL ;
KUEHL, TJ .
PEDIATRIC RESEARCH, 1987, 21 (06) :594-602
[6]  
Gerstmann DR, 1996, PEDIATRICS, V98, P1044
[7]   COMPARISON OF CONVENTIONAL AND HIGH-FREQUENCY VENTILATION - OXYGENATION AND LUNG PATHOLOGY [J].
HAMILTON, PP ;
ONAYEMI, A ;
SMYTH, JA ;
GILLAN, JE ;
CUTZ, E ;
FROESE, AB ;
BRYAN, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (01) :131-138
[8]   Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators [J].
Hatcher, D ;
Watanabe, H ;
Ashbury, T ;
Vincent, S ;
Fisher, J ;
Froese, A .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1081-1088
[9]  
HENDERSONSMART DJ, 2001, COCHRANE LIB
[10]  
HIFI Study Group, 1989, N Engl J Med, V320, P88