Age-dependent organ and effective dose coefficients for external photons: a comparison of stylized and voxel-based paediatric phantoms

被引:29
作者
Lee, Choonik
Lee, Choonsik
Bolch, Wesley E. [1 ]
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, ALRADS, Adv Lab Radiat Dosimetry Studies, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Nucl Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
关键词
D O I
10.1088/0031-9155/51/18/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This present study investigates the anatomical realism of conventional stylized models of children by comparing organ dose conversion coefficients for the ORNL paediatric phantom series with those determined in the UF ( University of Florida) voxel paediatric phantoms. The latter includes whole-body models of a 9 month male, 4 year female, 8 year female, 11 year male and a 14 year male. Of these phantoms, the 1 year, 5 year and 10 year ORNL phantoms, and 9 month male, 4 year female and 11 year male UF voxel phantoms were selected for side-by-side comparisons under idealized external photon irradiation. Organ absorbed dose per unit air kerma (Gy/Gy) for various radiosensitive organs and tissues were calculated for monoenergetic photons over the energy range of 15 keV to 10 MeV and for six irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT), left lateral (LLAT), rotational (ROT) and isotropic (ISO). Differences in organ dose conversion coefficients for the gonads, bone marrow, colon, lung and stomach, to which prominent tissue weighting factors are assigned, were depicted and analysed. Two major causes of observed differences were suggested: differences in organ shape and position and the differences in tissue shielding by overlying tissue regions within the phantoms. Significant discrepancies caused by anatomical differences between the two types of phantoms are also reported for several organs, and in particular, the thyroid and urinary bladder. The results of this study suggest that the paediatric series of ORNL phantoms also have less realistic internal organ and body anatomy and that dose conversion coefficients from these stylized phantoms should be re-evaluated using paediatric voxel phantoms.
引用
收藏
页码:4663 / 4688
页数:26
相关论文
共 45 条
[1]  
[Anonymous], 1996, ICRP PUBL, V74
[2]  
*BEIR, 2005, BEIR 7 PHAS 2
[3]   Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :163-183
[4]   Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-MAN tomographic model [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :203-214
[5]   Age-dependent protection quantities for external neutron irradiation [J].
Chou, DP ;
Wang, JN ;
Chen, IA ;
Chang, BJ .
RADIATION PROTECTION DOSIMETRY, 2003, 104 (01) :5-16
[6]   Age-dependent protection quantities for external photon irradiation [J].
Chou, DP ;
Wang, JN ;
Chen, IJ .
RADIATION PROTECTION DOSIMETRY, 2001, 95 (03) :215-223
[7]  
Cristy M, 1980, MATH PHANTOMS REPRES
[8]  
CRISTY M, 1987, ORNLTM8381, V1
[9]   Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields [J].
Dimbylow, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (06) :1047-1070
[10]   Adult female voxel models of different stature and photon conversion coefficients for radiation protection [J].
Fill, UA ;
Zankl, M ;
Petoussi-Henss, N ;
Siebert, M ;
Regulla, D .
HEALTH PHYSICS, 2004, 86 (03) :253-272