Effects of changes in blood pressure and airway pressures on parameters of fluid responsiveness

被引:41
作者
Sakka, Samir G. [1 ]
Becher, Lutz [2 ]
Kozieras, Jan [3 ]
van Hout, Nicole [3 ]
机构
[1] Univ Witten Herdecke, Dept Anaesthesiol & Intens Care Med, Med Ctr Cologne Merheim, D-51109 Cologne, Germany
[2] Cent Clin, Dept Anaesthesiol & Intens Care Med, Bad Berka, Thuringia, Germany
[3] Univ Jena, Jena, Thuringia, Germany
关键词
cardiac surgery; haemodynamic monitoring; stroke volume variation; systolic pressure variation; transpulmonary thermodilution technique; STROKE VOLUME VARIATION; CRITICALLY ILL PATIENTS; CENTRAL VENOUS-PRESSURE; MECHANICALLY VENTILATED PATIENTS; CARDIAC FILLING PRESSURES; CAPILLARY WEDGE PRESSURE; EXTRAVASCULAR LUNG WATER; TIDAL VOLUME; PRELOAD INDICATORS; SURGERY;
D O I
10.1097/EJA.0b013e32831ac31b
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background and objective Systolic pressure variation (SPV) and stroke volume variation (SVV) are clinical indicators of fluid responsiveness. However, several factors may influence these parameters and thereby limit their usefulness. In this clinical study, we analysed SPV and SVV in comparison with static preload parameters during an increase in arterial blood pressure (BP) and airway pressure. Methods We studied 16 postoperative cardiac surgical and mechanically ventilated patients who, for clinical reasons, underwent haemodynamic monitoring by transpulmonary thermodilution (PiCCO, Pulsion Medical Systems, Munich, Germany) and continuously received norepinephrine. After baseline, the systolic BP was increased (from 105 +/- 10 to 135 +/- 14 mmHg) by briefly increasing the norepinephrine dosage and, after a return to baseline level, the tidal volume was increased from 6 to 10 ml kg(-1). Final measurements were again taken at baseline airway pressures. At each time point, three boluses of 15 ml of 0.9% saline solution (<8 degrees C) were injected into a central vein. Fluid status and sedation remained unchanged. Friedman ANOVA on ranks for repeated measurements was used for statistical analysis. Results Heart rate (HR), cardiac index, intrathoracic blood volume and extravascular lung water remained constant throughout. However, the SPV (6 +/- 3 versus 5 +/- 2 mmHg) remained unchanged and the SVV decreased (12 +/- 5 versus 10 +/- 4%) with higher BP, whereas both parameters, in contrast to central venous and left atrial pressure, significantly increased with higher tidal volume. Conclusion In cardiac surgical patients with preserved cardiac index, SVV, but not SPV, decreased during an acute increase in BP, whereas both parameters, in contrast to cardiac filling pressures, significantly increased with higher tidal volume. Eur J Anaesthesiol 26:322-327 (c) 2009 European Society of Anaesthesiology.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 22 条
[1]
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[2]
Changes in central venous pressure and pulmonary capillary wedge pressure do not indicate changes in right and left heart volume in patients undergoing coronary artery bypass surgery [J].
Buhre, W ;
Weyland, A ;
Schorn, B ;
Scholz, M ;
Kazmaier, S ;
Hoeft, A ;
Sonntag, H .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (01) :11-17
[3]
The influence of tidal volume on the dynamic variables of fluid responsiveness in critically III patients [J].
Charron, C ;
Fessenmeyer, C ;
Cosson, C ;
Mazoit, JX ;
Hebert, JL ;
Benhamou, D ;
Edouard, AR .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1511-1517
[4]
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume [J].
De Backer, D ;
Heenen, S ;
Piagnerelli, M ;
Koch, M ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (04) :517-523
[5]
Echt M, 1974, CIRC RES, V40, P61
[6]
Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Lamm, P ;
Mair, H ;
Reichart, B .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (05) :533-539
[7]
Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload [J].
Kubitz, J. C. ;
Annecke, T. ;
Forkl, S. ;
Kemming, G. I. ;
Kronas, N. ;
Goetz, A. E. ;
Reuter, D. A. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (05) :591-597
[8]
Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload [J].
LichtwarckAschoff, M ;
Beale, R ;
Pfeiffer, UJ .
JOURNAL OF CRITICAL CARE, 1996, 11 (04) :180-188
[9]
INTRATHORACIC BLOOD-VOLUME ACCURATELY REFLECTS CIRCULATORY VOLUME STATUS IN CRITICALLY ILL PATIENTS WITH MECHANICAL VENTILATION [J].
LICHTWARCKASCHOFF, M ;
ZERAVIK, J ;
PFEIFFER, UJ .
INTENSIVE CARE MEDICINE, 1992, 18 (03) :142-147
[10]
Predicting fluid responsiveness in ICU patients - A critical analysis of the evidence [J].
Michard, F ;
Teboul, JL .
CHEST, 2002, 121 (06) :2000-2008