MRI of bone marrow disorders

被引:83
作者
Vanel, D [1 ]
Dromain, C [1 ]
Tardivon, A [1 ]
机构
[1] Inst Gustave Roussy, Dept Radiol, F-94805 Villejuif, France
关键词
bone marrow; MRI; MRI sequences;
D O I
10.1007/s003300050038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Four factors can be used in MR of bone marrow: fat-water distribution, artifacts induced by bone trabeculae, diffusion, and uptake of contrast media. Fat-water is imaged using T1-weighted spin-echo, short tau inversion recovery (STIR), and fast STIR, in- and out-of-phase gradient echo, and fat pre-saturation sequences, bone trabeculae by gradient echo with long TE; diffusion by single-shot spin-echo of contrast media is a more efficient way to improve the specificity. The value and limitations of those sequences are discussed in marrow replacements (metastases, lymphoma, leukemia) and in myeloid hyperplasia or depletion.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 21 条
[21]  
2-5