Evaluation of capillary zone electrophoresis and micellar electrokinetic capillary chromatography with direct injection of plasma for the determination of cefotaxime and its metabolite

被引:26
作者
Penalvo, GC
Kelly, M
Maillols, H
Fabre, H
机构
[1] UNIV MONTPELLIER 1,FAC PHARM,CHIM ANALYT LAB,F-34060 MONTPELLIER,FRANCE
[2] UNIV MONTPELLIER 1,FAC PHARM,LAB TECH PHARMACEUT IND,F-34060 MONTPELLIER,FRANCE
[3] UNIV CASTILLA LA MANCHA,DEPT QUIM ANALIT & TECNOL ALIMENTOS,E-13071 CIUDAD REAL,SPAIN
[4] ROYAL COLL SURGEONS IRELAND,DEPT CHEM,DUBLIN 2,IRELAND
关键词
D O I
10.1021/ac9605049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative aspects of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) were investigated for the determination of cefotaxime (C) and its deacetyl metabolite (DA) in human plasma in a concentration range of therapeutic interest, For CZE, plasma samples spiked with C and DA were injected after deproteinization with acetonitrile, and analytes were separated in a fused silica capillary using a berate buffer at pH 9.2 as electrolyte; no suitable internal standard was found, For MECC, plasma samples spiked with C, DA, and theobromine as internal standard were directly injected after dilution with water and analyzed using a phosphate buffer, pH 8.00, containing 165 mM SDS as separation electrolyte and a fused silica capillary, Both methods gave satisfactory interday precision with respect to migration times (RSD < 1%) and gave linear responses over the concentration ranges investigated (5-100 mg L(-1) C and 5-20 mg L(-1) DA), For CZE, intraday RSD (n = 4 graphs) between the slopes of the calibration graphs was acceptable (5.7%) for C, The corresponding figures for interday precision (n = 4 days) were fair (16.1%) in comparison to those obtained with MECC, for which the RSD was 1.49% when theobromine was used as internal standard, A satisfactory interday precision between slopes was also obtained with MECC even without the use of an internal standard (RSD = 4.38%), which demonstrated the ruggedness of this method, Detection limits (S/N = 3) were about 2 mg L(-1) (CZE) and 1 mg L(-1) in plasma (MECC) for C and DA. MECC was shown to be superior with regard to simplicity, rapidity, precision, and sensitivity.
引用
收藏
页码:1364 / 1369
页数:6
相关论文
共 13 条
[11]  
SHIABI ZK, 1993, J CHROMATOGR A, V652, P471
[12]   CLINICAL AND FORENSIC APPLICATIONS OF CAPILLARY ELECTROPHORESIS [J].
THORMANN, W ;
MOLTENI, S ;
CASLAVSKA, J ;
SCHMUTZ, A .
ELECTROPHORESIS, 1994, 15 (01) :3-12
[13]   EFFECT OF PH AND SODIUM DODECYL-SULFATE CONCENTRATION ON THE ANALYTICAL WINDOW IN THE DIRECT-INJECTION ANALYSIS OF PLASMA SAMPLES BY CAPILLARY ELECTROPHORESIS [J].
WATZIG, H ;
LLOYD, DK .
ELECTROPHORESIS, 1995, 16 (01) :57-63