Acousto-optical deflection-based whole channel scanning for microchip isoelectric focusing with laser-induced fluorescence detection

被引:34
作者
Sanders, JC [1 ]
Huang, ZL
Landers, JP
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] Univ Virginia, Dept Pathol, Charlottesville, VA 22904 USA
关键词
D O I
10.1039/b107835f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the development of a technique amenable to the separation of proteins on a microchip by isoelectric focusing (IEF) with entire channel scanning laser-induced fluorescence detection using acousto-optical deflection (AOD). The ability to use AOD to scan the portions of or the entire length of an IEF separation channel allows for high-speed analysis since the mobilization step is circumvented with this technique. Employing no moving parts eliminates mechanical noise and, not only is there no loss of resolution, AOD scanning can potentially increase resolution. The ability of AOD to provide ultra-fast scanning rates (kHz timescale) allows for real-time imaging of the focusing process. This is demonstrated with the separation of naturally fluorescent proteins using entire channel (total scanning range of 2.4 cm) AOD-mediated scanning laser-induced fluorescence detection.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 39 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   High-speed, random-access fluorescence microscopy .1. High-resolution optical recording with voltage-sensitive dyes and ion indicators [J].
Bullen, A ;
Patel, SS ;
Saggau, P .
BIOPHYSICAL JOURNAL, 1997, 73 (01) :477-491
[3]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[4]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[5]   HIGHLY SENSITIVE OPTICAL MEASUREMENT TECHNIQUES BASED ON ACOUSTOOPTIC DEVICES [J].
GASS, PA ;
SCHALK, S ;
SAMBLES, JR .
APPLIED OPTICS, 1994, 33 (31) :7501-7510
[6]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[7]  
HEMPE JM, 1994, CLIN CHEM, V40, P2288
[8]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[9]   Adaptation of capillary isoelectric focusing to microchannels on a glass chip [J].
Hofmann, O ;
Che, DP ;
Cruickshank, KA ;
Müller, UR .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :678-686
[10]   Capillary isoelectric focusing without carrier ampholytes [J].
Huang, TM ;
Wu, XZ ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4758-4761