Evaluation of an annular denuder tubes for atmospheric PAH partitioning studies-1: evaluation of the trapping efficiency of gaseous PAHS

被引:29
作者
Temime-Roussel, B [1 ]
Monod, A [1 ]
Massiani, C [1 ]
Wortham, H [1 ]
机构
[1] Univ Aix Marseille 1, Lab Chim & Environm, F-13331 Marseille, France
关键词
annular denuder; gaseous PAH; air sampling;
D O I
10.1016/j.atmosenv.2004.01.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper is an evaluation of the gas phase collection efficiency of a commercially available annular denuder sampler used to collect gas and particle phase semivolatile organic compounds. Laboratory and field experiments were carried out to determine the gas phase collection efficiency using naphthalene as reference compound. Laboratory tests were performed to study the influence of environmental conditions (temperature, relative humidity and gas phase concentration) and sampling conditions (sampling flow rate, and sampling duration) on the collection efficiency. During laboratory experiments, the collection efficiency of the gas phase was measured using a dynamic gas generator. It was above 90% for a range of experimental conditions covering: temperature from 9degreesC to 39degreesC, relative humidity from 30% to 90%, sampling duration up to 14h, flow rate of 1 and 2m(3)h(-1) and quantity of gaseous naphthalene considerably higher than the one usually collected during atmospheric sampling. Additionally, field experiments were carried out to test the matrix effect on the denuder performances. During these field experiments, and because the gaseous and particle atmospheric phases were trapped and analysed separately, it was possible to calculate the collection efficiency of the most volatile polycyclic aromatic hydrocarbons (PAHs). It was 100% assuming a relative standard deviation of 10% on this calculation. This set of results shows that the denuder-based sampling method is suitable for the sampling of the most volatile PAHs. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1913 / 1924
页数:12
相关论文
共 32 条
[2]   DESIGN AND PERFORMANCE OF A HIGH-VOLUME COMPOUND ANNULAR DENUDER [J].
COUTANT, RW ;
CALLAHAN, PJ ;
KUHLMAN, MR ;
LEWIS, RG .
ATMOSPHERIC ENVIRONMENT, 1989, 23 (10) :2205-2211
[3]   EFFICIENCY OF SILICONE-GREASE-COATED DENUDERS FOR COLLECTION OF POLYNUCLEAR AROMATIC-HYDROCARBONS [J].
COUTANT, RW ;
CALLAHAN, PJ ;
CHUANG, JC ;
LEWIS, RG .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (15) :2831-2834
[4]   A MULTIPLE-SYSTEM, MULTICHANNEL DIFFUSION DENUDER SAMPLER FOR THE DETERMINATION OF FINE-PARTICULATE ORGANIC MATERIAL IN THE ATMOSPHERE [J].
EATOUGH, DJ ;
WADSWORTH, A ;
EATOUGH, DA ;
CRAWFORD, JW ;
HANSEN, LD ;
LEWIS, EA .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (08) :1213-1219
[5]   Integrated and real-time diffusion denuder sampler for PM2.5 [J].
Eatough, DJ ;
Obeidi, F ;
Pang, YB ;
Ding, YM ;
Eatough, NL ;
Wilson, WE .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (17) :2835-2844
[6]  
Gundel L, 1999, GAS PARTICLE PHASE M, P287
[7]   DIRECT DETERMINATION OF THE PHASE DISTRIBUTIONS OF SEMIVOLATILE POLYCYCLIC AROMATIC-HYDROCARBONS USING ANNULAR DENUDERS [J].
GUNDEL, LA ;
LEE, VC ;
MAHANAMA, KRR ;
STEVENS, RK ;
DAISEY, JM .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (14) :1719-1733
[8]   POTENTIAL CONTAMINATION FROM THE USE OF SYNTHETIC ADSORBENTS IN AIR SAMPLING PROCEDURES [J].
HUNT, G ;
PANGARO, N .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :369-372
[9]  
KAMENS RM, 1997, ENVIRON SCI TECHNOL, V31, P469
[10]  
KAMENS RM, 1999, GAS PARTICLE PHASE M, P333