Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip

被引:41
作者
Chen, Wei [2 ,3 ]
Peng, Chifang [2 ,3 ]
Jin, Zhengyue [2 ,3 ]
Qiao, Ruirui [4 ]
Wang, Wuyang [5 ]
Zhu, Shuifang [6 ]
Wang, Libing [7 ]
Jing, Qinhui [1 ]
Xu, Chuanlai [2 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[2] Jiangnan Univ, Sch Food Sci & Technol, Wuxi 214122, Peoples R China
[3] Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Peoples R China
[4] Chinese Acad Sci, Inst Chem, Beijing 10008, Peoples R China
[5] Fourth Hosp Wuxi, Wuxi 214036, Peoples R China
[6] Chinese Acad Inspect & Quarantine, Beijing 10008, Peoples R China
[7] Tianjin Acad Inspect & Quarantine, Tianjin 300457, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasensitive; Immunoassay; 7-Aminoclonazepam; CdTe nanoparticle; Microfluidic Chip; LC/MS/MS; BENZODIAZEPINE-LIKE SUBSTANCES; QUANTUM-DOTS; WHOLE-BLOOD; ORAL FLUID; ELISA; PERFORMANCE; METABOLITES; EXTRACTION;
D O I
10.1016/j.bios.2008.10.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The present paper described a rapid and ultrasensitive detection method using a microfluidic chip for analyzing 7-aminoclonazepam (7-ACZP) residues in human urine. A microfluidic chip-based immunoassay with laser-induced fluorescence (LIF) detection based on the water-soluble denatured bovine serum albumin (dBSA)-coated CdTe quantum dots (QDs) was prepared for the ultrasensitive detection of 7-ACZP. The whole procedure including the chip and the control software was designed and constructed in our own laboratory. The detection of 7-ACZP could be completed within 5 min. The results demonstrated that under the optima conditions, 7-ACZP residues could be detected with a precision of 5% relative standard deviation (RSD), and the linear range and the limit of detection (LOD) for 7-ACZP were 1.1-60.1 and 0.021 ng mL(-1), respectively. This method was compared with ELISA and showed a good correlation. This microfluidic chip with LIF detection was applied to the determination of 7-ACZP residues in positive human urine samples, and the results were confirmed by high-performance liquid chromatography and tandem mass spectrometry (LC/MS/MS). This ultrasensitive detection technique was proved to be practical for clinical use. Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2051 / 2056
页数:6
相关论文
共 25 条
  • [1] GUIDELINES FOR THE RATIONAL USE OF BENZODIAZEPINES - WHEN AND WHAT TO USE
    ASHTON, H
    [J]. DRUGS, 1994, 48 (01) : 25 - 40
  • [2] Enhancement effect of illumination on the photoluminescence of water-soluble CdTe nanocrystals: Toward highly fluorescent CdTe/CdS core-shell structure
    Bao, HB
    Gong, YJ
    Li, Z
    Gao, MY
    [J]. CHEMISTRY OF MATERIALS, 2004, 16 (20) : 3853 - 3859
  • [3] Borrey D, 2002, CLIN CHEM, V48, P2047
  • [4] Quantum dot bioconjugates for ultrasensitive nonisotopic detection
    Chan, WCW
    Nie, SM
    [J]. SCIENCE, 1998, 281 (5385) : 2016 - 2018
  • [5] ELISA detection of clonazepam and 7-aminoclonazepam in whole blood and urine
    Elian, AA
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2003, 134 (01) : 54 - 56
  • [6] Detection of single bacterial pathogens with semiconductor quantum dots
    Hahn, MA
    Tabb, JS
    Krauss, TD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (15) : 4861 - 4869
  • [7] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897
  • [8] Determination of benzodiazepines in human urine using solid-phase extraction and high-performance liquid chromatography-electrospray ionization tandern mass spectrometry
    Hegstad, S
    Oiestad, EL
    Johansen, U
    Christophersen, AS
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2006, 30 (01) : 31 - 37
  • [9] Characterization of the coupling of quantum dots and immunoglobulin antibodies
    Hua, Xiao-Feng
    Liu, Tian-Cai
    Cao, Yuan-Cheng
    Liu, Bo
    Wang, Hai-Qiao
    Wang, Jian-Hao
    Huang, Zhen-Li
    Zhao, Yuan-Di
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (06) : 1665 - 1671
  • [10] Quantum dot-based immunosensor for the detection of prostate-specific antigen using fluorescence microscopy
    Kerman, Kagan
    Endo, Tatsuro
    Tsukamoto, Masatoshi
    Chikae, Miyuki
    Takamura, Yuzuru
    Tamiya, Eiichi
    [J]. TALANTA, 2007, 71 (04) : 1494 - 1499