Comparison of long-term variability for standard and short-wavelength automated perimetry in stable glaucoma patients

被引:53
作者
Blumenthal, EZ
Sample, PA
Zangwill, L
Lee, AC
Kono, Y
Weinreb, RN
机构
[1] Glaucoma Ctr 0946, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, Visual Funct Lab, San Diego, CA 92103 USA
关键词
D O I
10.1016/S0002-9394(99)00432-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To quantify and compare, on a point-by-point basis, the long-term variability of standard and short-wavelength automated perimetry in a group of stable glaucoma patients. METHODS: From a group of 53 glaucoma patients experienced in visual field testing, we identified one eye, randomly chosen, from each of 25 glaucoma patients whose condition was found to be stable, based on both standard and short-wavelength automated perimetry visual field criteria. On each of three visits during a period of up to 3 months, each patient performed one standard and one short-wavelength automated perimetry 24-2 visual field in a random order on a Humphrey visual field analyzer. The long-term variability (also referred to as test-retest variability) was defined as the SD of the three threshold decibel values at each test location. The longterm variability for each test point (mean +/- SD) was determined separately for both standard visual fields and short-wavelength automated perimetry. RESULTS: With all 52 test locations of the 24-2 field averaged, the global long-term variability, mean (+/- SD) for standard visual fields and short-wavelength automated perimetry was 2.37 +/- 2.03 dB (95% confidence interval, 2.26-2.48 dB) and 2.92 +/- 2.03 dB (95% confidence interval, 2.81-3.03 dB), respectively (P < .0001). In 16 of the 52 visual field locations, long-term variability on short-wavelength automated perimetry was significantly higher than long-term variability on standard visual fields. In addition, the long-term variability increased with greater distance from the point of fixation for both standard visual fields and short-wavelength automated perimetry. The long-term variability decreased closer to fixation, more for standard visual fields than for short-wavelength automated perimetry. CONCLUSIONS: In a group of stable glaucoma patients, mean long-term variability was 0.55 dB higher for short-wavelength automated perimetry than for standard visual fields. This needs to be taken into consideration when serial visual fields are evaluated for change. (C) 2000 by Elsevier Science Inc, All rights reserved.
引用
收藏
页码:309 / 313
页数:5
相关论文
共 10 条
[1]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[2]  
HEIJL A, 1987, ARCH OPHTHALMOL-CHIC, V105, P1544
[3]   TEST-RETEST VARIABILITY IN GLAUCOMATOUS VISUAL-FIELDS [J].
HEIJL, A ;
LINDGREN, A ;
LINDGREN, G .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (02) :130-135
[4]   BLUE-ON-YELLOW PERIMETRY CAN PREDICT THE DEVELOPMENT OF GLAUCOMATOUS VISUAL-FIELD LOSS [J].
JOHNSON, CA ;
ADAMS, AJ ;
CASSON, EJ ;
BRANDT, JD .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :645-650
[5]   PROGRESSION OF EARLY GLAUCOMATOUS VISUAL-FIELD LOSS AS DETECTED BY BLUE-ON-YELLOW AND STANDARD WHITE-ON-WHITE AUTOMATED PERIMETRY [J].
JOHNSON, CA ;
ADAMS, AJ ;
CASSON, EJ ;
BRANDT, JD .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :651-656
[6]   Test-retest variability of blue-on-yellow perimetry is greater than white-on-white perimetry in normal subjects [J].
Kwon, YH ;
Park, HJ ;
Jap, A ;
Ugurlu, S ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) :29-36
[7]  
SAMPLE PA, 1992, INVEST OPHTH VIS SCI, V33, P2068
[8]   SHORT-WAVELENGTH COLOR VISUAL-FIELDS IN GLAUCOMA SUSPECTS AT RISK [J].
SAMPLE, PA ;
TAYLOR, JDN ;
MARTINEZ, GA ;
LUSKY, M ;
WEINREB, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (02) :225-233
[9]  
SAMPLE PA, 1993, TECHNICAL DIGEST SER, V3, P292
[10]  
Wild JM, 1998, INVEST OPHTH VIS SCI, V39, P54